The AirTAC GAC F.R.L. Unit GAC400C10ASWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air, the AirTAC GAC400C10ASWTK is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket with quick mounting clamps. This specific assembly handles a 3/8in port, features a robust metal bowl, and operates within the standard 0.15-0.9 MPa (20-130 psi) pressure range. A 5 um element traps fine particulates for precision pneumatics, while the fitted circular gauge reads in MPa/psi for the default NPT thread.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. The automatic drain clears condensate from the 100 cc sump without an operator, which is decisive for unattended or wet lines. This 2390 g unit also includes a reverse-flow (reflux) valve, shown as a separate pneumatic symbol in the catalogue, and replacement internals are available as GAF400-10, GAR400-10 and GAL400-10.
| Model | Airtac GAC F.R.L. Unit GAC400C10ASWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered 5 um air to precision machining centers, ensuring sensitive pneumatic tooling on a 3/8in line operates without particulate contamination.
Conditions air for multi-station assembly machinery where the automatic drain handles condensate continuously, preventing moisture from reaching moving actuators.
Feeds a steady, lubricated air supply to high-speed packaging conveyors, utilizing the metal bowl for durability in demanding industrial environments.
Choose this metal-bowl assembly when a machine requires fine 5 um filtration and unattended condensate management. The 100 cc drain bowl and 185 cc oil bowl drive the service interval, meaning fewer interventions than a smaller body. If your downstream line must remain completely oil-free, omit the lubricator and choose a separate filter-regulator instead. The fitted gauge allows operators to monitor the set pressure directly, and the NPT thread sets the MPa/psi scale. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, which is double the GAC300's 3000 L/min envelope, giving clear room to size up or down. Finally, the 1.5 MPa (215 psi) proof pressure against a 1.0 MPa (145 psi) maximum provides a 1.5x burst-test margin, not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, features a 100 cc drain bowl and a 185 cc oil bowl, weighs 2390 g, and uses ISO VG 32 lubricant.
The K indicates that a reverse-flow (reflux) valve is fitted to this assembly. The catalogue shows this as a separate pneumatic symbol with details on its own page, and it is included as an ordering difference on this specific unit.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.