The AirTAC GAC F.R.L. Unit GAC400C10LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAC400C10LNT is a three-unit F.R.L. combination - filter, regulator and lubricator - pre-assembled on one L-shape bracket with quick mounting clamps. The metal bowl protects the 100 cc condensate chamber and 185 cc oil reservoir, and the 3/8in port suits it to medium-duty machine circuits. It regulates from 0.15 to 0.4 MPa (20-58 psi) and filters to 40 um.
Air passes through the filter first, then the regulator, and the lubricator adds oil mist last - downstream of the regulator seat, so the oil never fouls pressure control. At 2390 g, this unit needs a proper panel or frame mount rather than support from the tubing. The lower-pressure range caps at 0.4 MPa, so it is the right choice only for circuits that never need more than that ceiling. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C10LNT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feed a delicate press-fit or insertion fixture that must not see more than 0.4 MPa, where the lower-pressure regulator prevents over-force damage to small parts.
Supply a regulated air signal to pneumatic valves in a paint booth, where consistent low pressure keeps atomization stable and the metal bowl resists solvent splashes.
Power a benchtop test cylinder or air bearing in a calibration rig, where the 0.15-0.4 MPa range gives fine control for repeatable experiments.
Choose the GAC400C10LNT when your machine runs below 0.4 MPa and you want a metal bowl for a tougher environment. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand emptying. No gauge is supplied, so the set pressure cannot be read without adding one to the 1/4in gauge connection. The 40 um element handles standard shop air; step to a 5 um element if you need finer filtration. Spare parts for this body-port are GAF400-10, GAR400-10 and GAL400-10, all sharing the same suffix. The 0.4 MPa ceiling is about 44% of the standard type's 0.9 MPa limit, so confirm your circuit never needs more before locking in this lower-pressure version.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
It operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and it must not freeze. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The complete unit weighs 2390 g.
The C code specifies a metal bowl, which is a build choice for environments where a polycarbonate bowl might be less suitable - confirm compatibility for aggressive surroundings. The N after the port means no gauge is supplied; the 1/4in gauge connection is there if you add one later. The semi-auto drain and manual drain are both fitted.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.