The AirTAC GAC F.R.L. Unit GAC400C10LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in ported GAC400 body carries a 5 um element for trapping fine particulates ahead of precision valves, while the lower pressure type restricts the regulating band to 0.15-0.4 MPa (20-58 psi). A circular gauge reading MPa/psi is fitted for the default NPT thread.
Air passes through the filter first, then the regulator, with oil mist injected last so the internal seat stays clean. The metal bowl equips this specific unit, and the 100 cc condensate sump paired with a 185 cc oil reservoir sets the maintenance interval for a 2390 g assembly that requires a firm panel mount rather than tubing support. If the downstream line must stay completely free of oil, a dedicated filter-regulator should be chosen instead of this lubricated setup. Order code GAC400C10LWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C10LWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive directional control valves on a machining center using the 5 um element to prevent spool sticking.
Supplies the regulated 0.4 MPa ceiling needed to actuate delicate heat-sealing jaws without crushing the packaging film.
Conditions air for analytical equipment where the metal bowl offers solvent resistance against aggressive cleaning agents.
Choose this metal bowl variant for rugged environments where PC or nylon might not suit the ambient conditions, keeping in mind the shared 1.0 MPa maximum and -5 to 70 C limits apply equally across all materials. The semi-auto and manual drain combination fitted here dumps condensate on every pressure drop or on operator demand, contrasting with the automatic drain option available on other codes. Because the 5 um element catches far finer particles than the 40 um standard, expect more frequent element swaps to protect sensitive instrumentation. The constituent parts are separately orderable as GAF400-10, GAR400-10 and GAL400-10, meaning a clogged screen never forces replacing the whole assembly. Stepping down to the GAC300 shrinks the plotted flow envelope from 6000 L/min to 3000 L/min at 0.7 MPa inlet, but staying here provides double the air capacity. Crucially, the 0.4 MPa ceiling of this L type is 44% of the 0.9 MPa standard ceiling, so confirm your machinery will never require higher pressure before specifying this unit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) against a 1.0 MPa (145 psi) maximum and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, features a 5 um element, and uses ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl holds 185 cc, and the assembly weighs 2390 g.
The L in the ordering code designates the 0.15-0.4 MPa range, making it suitable for low-force actuators rather than general factory air. If the machine might ever need more than 0.4 MPa, this is the wrong part, as turning the adjustment screw beyond that ceiling is mechanically prevented.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.