The AirTAC GAC F.R.L. Unit GAC400C10SNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air, this GAC400C10SNTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket with quick clamps. The 3/8in port pairs with a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
Weighing 2390 g, this body requires a solid panel or frame mount rather than tubing support. It features a durable metal bowl and omits the pressure gauge entirely. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. If a gauge is needed later, the unit has a 1/4in connection ready for installation. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C10SNTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic wrenches and actuators on a vehicle production track, relying on the 100 cc condensate bowl for extended shifts between maintenance intervals.
Prepares air for continuous packaging equipment where the 40 um element protects precision moving parts from particulate ingress.
Supplies stable, lubricated air to pneumatic tool change systems, ensuring reliable gripping and release operations under varying shop demand.
Choose this 3/8in port model for medium-duty pneumatics, stepping up from the GAC300 which offers a 3000 L/min plotted flow envelope at 0.7 MPa inlet to this GAC400's 6000 L/min envelope. The metal bowl suits harsher industrial settings compared to standard PC or nylon options. Because the N code follows the port, no gauge is supplied; operators must add one to the 1/4in connection to read the set pressure. The semi-auto and manual drain pair is fitted, dumping condensate on pressure drops or on demand. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. Spares are available as GAF400-10, GAR400-10 and GAL400-10. Stepping up from the GAC300 to this body roughly doubles the flow envelope, while the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C. The drain bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 2390 g. The recommended lubricant is ISO VG 32.
The N in the code means no gauge is supplied; you can install one using the 1/4in gauge connection. The K indicates a reverse-flow (reflux) valve is fitted, which the catalogue details as a separate pneumatic symbol on its own page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.