verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC200C08LK

The AirTAC GAFC Air Service Unit GAFC200C08LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight590 g
$73.27 $81.91Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAFC200-08 bowl, type and element option on one page All GAFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAFC Air Service Unit GAFC200C08LK

This AirTAC GAFC200C08LK is a two-piece F.R.L. combination: the filter and regulator share one body, and a lubricator is joined to it on a T-bracket with quick clamps. It is built for a 1/4in port and operates in the lower-pressure band of 0.15-0.4 MPa (20-58 psi), with a 40 um element filtering the air before pressure is set. The metal bowl is specified by the C code, and the semi-auto and manual drains are both fitted for condensate removal.

The two-piece layout means there is one less inter-unit joint to seal compared with a three-body filter, regulator and lubricator train. Air is cleaned and regulated in the first body, then the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. At 590 g, this size class suits a compact machine or a single actuator station, and the 25 cc drain bowl with 36 cc oil bowl sets the service rhythm for the unit.

Airtac GAFC Air Service Unit GAFC200C08LK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC200C08LK
SeriesGAFC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC200C08LK

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/4" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC200C08LK Is Used

precision_manufacturing

Precision pressure setting

Set a precise 0.3 MPa for a small indexing table or a light press, where the lower-pressure range gives finer adjustment authority than a standard 0.9 MPa regulator.

build

Compact machine build

Fit this 590 g unit on a small assembly station or a benchtop fixture where a 1/4in port matches the air prep needs of a single pneumatic cylinder.

science

Lab air preparation

Use it to supply clean, regulated, lubricated air to a small test rig or a laboratory actuator that runs below 0.4 MPa and needs a consistent oil mist.

Is the Airtac GAFC Air Service Unit GAFC200C08LK the Right Air-Prep Unit?

Choose the GAFC200C08LK when your circuit needs a 1/4in port and a regulated ceiling of 0.4 MPa. The L type tops out at 0.4 MPa, so if the machine may ever require more than that, step to the standard S type instead. The metal bowl is a build choice, but the catalogue gives no impact or chemical data for it, so confirm it suits your surroundings. The circular gauge is fitted and reads in MPa and psi for the PT thread. The reverse-flow (reflux) valve is fitted, and the catalogue draws it as a separate pneumatic symbol. Spare parts are orderable as the GAFR200-08 filter & regulator and the GAL200-08 lubricator, both matching this body and port. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated band, so plan the inlet pressure accordingly.

AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC200C08LK FAQ

The GAFC200C08LK is a lower-pressure F.R.L. combination with a working range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 25 cc and the oil bowl holds 36 cc. Recommended lubricant is ISO VG 32. The unit weighs 590 g and has a 1/4in port.

The C code specifies a metal bowl, which is a build choice for the unit. The catalogue does not provide impact or chemical resistance data for the material, so confirm it fits your environment. The K code means a reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol. The semi-auto and manual drains are both fitted on this model.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC200C08LK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAFC200C08LK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.