The AirTAC GAFC Air Service Unit GAFC200C08LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC200C08LWK is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is mounted beside them on a T-bracket. It handles a 1/4in port and regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element for finer filtration.
The metal bowl holds 25 cc of condensate and the oil bowl 36 cc, and the whole unit weighs 590 g. The circular gauge reads in MPa and psi, and a reverse-flow valve is fitted. Its catalogue flow curve is plotted to 1750 L/min at 0.7 MPa inlet, useful for sizing against a real duty point.
| Model | Airtac GAFC Air Service Unit GAFC200C08LWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a delicate 0.3 MPa for a small clamping cylinder on a benchtop fixture, where the lower range gives finer adjustment than a standard regulator.
Feed a lab-scale pneumatic actuator or a test rig that must not see pressure above 0.4 MPa, protecting sensitive components from over-pressure.
Power a small air tool or a blow-off station in a repair bay, where the 1/4in port and 5 um element keep the line clean and the pressure gentle.
Choose this lower-pressure model when your circuit needs a gentle, precise 0.15-0.4 MPa band. The metal bowl is specified by the C code, and the semi-auto drain dumps condensate on each pressure drop while the manual drain gives on-demand control. The 5 um element suits sensitive valves, and the PT thread carries a dual MPa-psi gauge scale.
The two units are orderable separately as GAFR200-08 and GAL200-08, so a worn element or bowl does not force a full replacement. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
It regulates air from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and needs ISO VG 32 oil. The drain bowl holds 25 cc, the oil bowl 36 cc, and the unit weighs 590 g.
The C code specifies a metal bowl, which is a build choice you should confirm suits your environment. The K code means a reverse-flow (reflux) valve is fitted, shown as a separate symbol in the catalogue. The semi-auto drain clears condensate when pressure drops, and the manual drain works on demand.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.