The AirTAC GAFC Air Service Unit GAFC200C08SK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC200C08SK is a two-piece F.R.L. combination: a GAFR filter-regulator shares one body, and a GAL lubricator mounts beside it on a T-bracket with quick clamps. Air enters the 1/4in port, gets filtered and regulated to 0.15-0.9 MPa (20-130 psi), then receives a metered oil mist from the lubricator as the last step. The metal bowl (C code) holds 25 cc of condensate, while the oil bowl holds 36 cc; the whole unit weighs 590 g.
The 40 um element handles standard shop air, and the circular gauge reads in MPa/psi for the default PT thread. A reverse-flow (reflux) valve is fitted per the K code, shown as a separate symbol in the catalogue. Since the filter and regulator are one casting, there is one less inter-unit joint to seal compared to a three-piece filter-regulator-lubricator train of the same port size.
| Model | Airtac GAFC Air Service Unit GAFC200C08SK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic clamp on a benchtop assembly fixture with clean, regulated, lubricated air at 1/4in port size. The 590 g unit mounts directly to a small panel or machine frame.
Supply a small arbor press or riveting tool that cycles frequently. The 25 cc condensate bowl and 36 cc oil bowl keep service intervals practical for a single-station operation.
Run a compact slide or gripper on a light assembly line. The 40 um element protects the valve, while the lubricator adds oil mist downstream of the regulator for the actuator seals.
Choose the GAFC200 body for small actuators, jigs, or single-station machines that need clean, regulated, lubricated air at modest flow. The 1/4in port suits short drops to a valve manifold or a compact cylinder. The metal bowl is a build choice for the shop floor, but the catalogue gives no impact or chemical data, so confirm it suits your environment. The semi-auto drain dumps condensate when pressure drops, and the manual drain gives on-demand control; the 40 um element is the standard grade. The gauge is fitted and reads MPa/psi, matching the PT thread. The reflux valve is present, and the two serviceable halves are orderable separately as GAFR200-08 and GAL200-08. If the line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. With a 1.0 MPa max supply, you have about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan the inlet pressure accordingly.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC200C08SK operates from 0.15 to 0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 25 cc, the oil bowl holds 36 cc, and the unit weighs 590 g. The port is 1/4in, the element is 40 um, and the thread is PT.
The C code specifies a metal bowl, which is a build choice for the application; the catalogue does not provide impact or chemical resistance data, so confirm it fits your environment. The K code means a reverse-flow (reflux) valve is fitted, as shown in the catalogue's pneumatic symbol. The filter and regulator are one unit, and the lubricator is the second piece, so the set is two pieces, not three.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.