The AirTAC GAFC Air Service Unit GAFC200C08SNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GAFC200C08SNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared bracket with quick clamps. Air enters the 1/4in port, gets filtered by the 5 um element, and is regulated to 0.15-0.9 MPa (20-130 psi) before the lubricator adds a metered oil mist downstream. The metal bowl and reverse-flow valve are part of this build, and the unit weighs 590 g.
Because the filter and regulator share one body, there is one less inter-unit joint to seal compared to a three-piece filter-regulator-lubricator train. The 25 cc condensate bowl and 36 cc oil bowl define the service interval, and the 5 um element traps finer particles for precision applications. No gauge is supplied; the 1/8in gauge connection allows adding one if needed.
| Model | Airtac GAFC Air Service Unit GAFC200C08SNWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic cylinder or a small precision valve station on a benchtop assembly fixture, where the 5 um element protects fine internal clearances.
Supply a small labeling or capping head on a packaging line, where the 1/4in port and 590 g weight fit tight machine frames without extra support.
Run a small air drill or screwdriver in a maintenance shop, with the lubricator adding ISO VG 32 oil mist to keep the tool spindle running smoothly.
Choose the GAFC200 for small actuators or single jigs needing clean, regulated, lubricated air at flows within the catalogue curve plotted to 1750 L/min at 0.7 MPa inlet. The metal bowl (C) is a build choice for the specified environment, though the shared -5 to 70 C and 1.0 MPa max rating apply regardless of material. The semi-auto drain dumps condensate on pressure drops, with a manual backup for on-demand emptying. The 5 um element suits precision valves but requires more frequent service than the 40 um standard. The reverse-flow (reflux) valve is fitted, and the PT thread carries a MPa/psi gauge scale if a gauge is added. Spares are orderable as GAFR200-08 and GAL200-08. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses ISO VG 32 lubricant, and has a 25 cc drain bowl plus a 36 cc oil bowl. The unit weighs 590 g and has a 1/4in port.
The N after the port code means no gauge is supplied with this unit. The gauge connection on the GAFC200 body is 1/8in, so you can add a compatible gauge later if you need to read the set pressure directly.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.