The AirTAC GAFC Air Service Unit GAFC200N08LNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC200N08LNK is an F.R.L. combination where the filter and regulator share one body, and a separate lubricator is mounted on the same bracket. It handles a 1/4in port and operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi), with a 40 um element. The nylon bowl is specified by the N before the port code, and the unit weighs 590 g.
The two-piece layout means there is one less inter-unit joint to seal compared to a three-body filter, regulator and lubricator train. Air is filtered and set to pressure in the first body, then the lubricator adds a controlled oil mist last, so oil never passes back through the regulator seat. This model has no gauge fitted, so the 1/8in gauge connection is left for a later addition if needed.
| Model | Airtac GAFC Air Service Unit GAFC200N08LNK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-acting clamp on a benchtop assembly jig where the actuator is sized for a 0.3 MPa grip force and the line pressure never needs to go higher.
Supply a small pneumatic test fixture on a laboratory bench where a regulated 0.25 MPa is the setpoint for a delicate diaphragm valve, and the lower range gives finer adjustment.
Prepare air for a manual spray gun in a paint booth where the regulator is set to 0.35 MPa and the lubricator adds a fine oil mist to the tool.
Choose this GAFC200N08LNK when your line needs 1/4in ports and a regulated ceiling of 0.4 MPa. The L type tops out at 0.4 MPa, so if the machine may ever need more, this is the wrong part. The nylon bowl is a build choice, but the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, and the manual drain is there for on-demand use. The reverse-flow (reflux) valve is fitted, and the catalogue draws it as a separate pneumatic symbol. The 40 um element is the standard grade. Spares are the GAFR200-08 filter-regulator and the GAL200-08 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC200N08LNK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C and it must not freeze. The drain bowl holds 25 cc and the oil bowl holds 36 cc. Recommended lubricant is ISO VG 32, and the unit weighs 590 g.
The N after the port code means no gauge is supplied with this unit. If you need to read the set pressure, you will have to add one. The gauge connection on a GAFC200 is 1/8in, so a standard 1/8in gauge can be fitted later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.