The AirTAC GAFC Air Service Unit GAFC200N08SK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC200N08SK is a compact F.R.L. combination built around a 1/4in port, with a nylon bowl and a 40 um element. The filter and regulator share one body, so the unit is two pieces on a T bracket rather than three, which reduces the number of inter-unit joints to seal. Air is cleaned and set to pressure in the first body, then the lubricator adds a metered oil mist last, so oil never passes back through the regulator seat.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. The 25 cc condensate bowl and 36 cc oil bowl are sized for a 590 g unit that suits a single actuator or small jig. A circular gauge is fitted, reading MPa/psi on the PT thread, and the reverse-flow (reflux) valve is included.
| Model | Airtac GAFC Air Service Unit GAFC200N08SK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a small clamping cylinder on a benchtop assembly jig with filtered, regulated air and a controlled oil mist for the actuator seals.
Supply a 1/4in-port pneumatic press with clean air at a set pressure, while the lubricator keeps the moving parts running smoothly.
Run a laboratory test fixture that cycles a small cylinder, using the 40 um element to protect the valve from particles in the supply.
Choose the GAFC200N08SK when a 1/4in port and a 590 g body fit the machine layout. The nylon bowl is a material choice, not a specification change - the 1.0 MPa maximum and -5 to 70 C range are identical across PC, metal and nylon, so confirm the material suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, while the manual drain works on demand; the 25 cc bowl sets the service interval. The 40 um element is the standard grade, and the PT thread carries a gauge scaled in MPa/psi. The reverse-flow (reflux) valve is fitted, and the two units are orderable separately as the GAFR200-08 filter & regulator and the GAL200-08 lubricator. With a 1.0 MPa max supply, there is about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the inlet pressure near 1.0 MPa if you need the full 0.9 MPa output.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC200N08SK operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 25 cc, the oil bowl holds 36 cc, and the unit weighs 590 g.
The K indicates the reverse-flow (reflux) valve is fitted. The catalogue shows it as a separate pneumatic symbol, and it is part of the ordering code for this model. The two main units are still the GAFR200-08 filter & regulator and the GAL200-08 lubricator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.