The AirTAC GAFC Air Service Unit GAFC200N08SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC200N08SNK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. It handles a 1/4in port, regulates from 0.15 to 0.9 MPa (20-130 psi), and filters to 40 um. The nylon bowl is specified by the N before the port code, and the gauge is omitted per the N after it, leaving a 1/8in gauge connection for later addition.
The build order matters: air is cleaned and pressure-set in the first body, then the lubricator adds a metered oil mist downstream, so oil never travels back through the regulator seat. With a 25 cc condensate bowl and a 36 cc oil bowl, this 590 g unit suits compact machines where space is tight. The reverse-flow (reflux) valve is fitted, and the catalogue shows it as a separate pneumatic symbol.
| Model | Airtac GAFC Air Service Unit GAFC200N08SNK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single pneumatic clamp or indexing fixture on a benchtop assembly station, where the 1/4in port and 590 g weight keep the setup light and the 40 um element protects small valves.
Supply a short-stroke cylinder on a blister-pack or carton-sealing cell, using the 25 cc condensate bowl to catch moisture from a humid plant line between scheduled maintenance rounds.
Power a portable pneumatic tool or a bench-mounted drill fixture in a repair shop, where the semi-auto drain clears water automatically on shutdown and the manual drain allows a quick check.
Choose this GAFC200N08SNK when you need a compact 1/4in F.R.L. set with a nylon bowl and a reverse-flow valve. The nylon bowl is a build choice; the shared specification (1.0 MPa max, -5 to 70 C) does not change with material, so confirm it suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, while the manual drain gives on-demand control. The 40 um element handles general shop air; step up to the 5 um W option for finer filtration if your valves need it. The PT thread carries a gauge scale of MPa/psi, but this unit ships without a gauge, so plan to add one via the 1/8in connection if you need to read set pressure. Spares are the GAFR200-08 filter-regulator and the GAL200-08 lubricator, both orderable separately. Since the lubricator adds oil mist, choose a plain GAFR instead if your line must stay oil-free. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan your inlet pressure accordingly.
AirtacDistr lists every GAFC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gafc200-08-two-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates from 0.15 to 0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and requires ISO VG 32 lubricant. The drain bowl holds 25 cc and the oil bowl holds 36 cc, with a total weight of 590 g. The port is 1/4in and the element grade is 40 um.
The N after the port code means no gauge is supplied, so you cannot read the set pressure without adding one; the 1/8in gauge connection is there for that purpose. The K code indicates a reverse-flow (reflux) valve is fitted, which the catalogue draws as a separate pneumatic symbol. This unit also has a nylon bowl, noted by the N before the port code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.