Airtac GAFC Air Service Unit GAFC200N08SW

Airtac

Airtac GAFC Air Service Unit GAFC200N08SW

$62.77 $70.27
sold in last hours
customers are viewing this product
Ask A Question
 
 
DELIVERY
Estimated delivery between and
Guarantee Safe Checkout
Airtac Online Distributors/Supplier Store
Description
1、Quick and reliable fixed connection for easy installation and operation;
2、Stable pressure regulation with high repeatability accuracy;
3、High-efficiency moisture and solid particle elimination capability:
4、Dual drainage options: differential pressure manual drainage or automatic drainage;
5、Multiple bowl material selections including polycarbonate (PC), metal, and nylon to adapt to diverse operational environments.

Category: F.R.L. Combination Units , Brand: AirTAC , Series: GAFC

AirTAC GAFC200N08SW Filter Regulator Lubricator (FRL) Unit Specifications

  • Model: GAFC200N08SW
  • Type: Compact inline filter regulator (2-stage combination)
  • Port size: PT3/4 (G3/4 optional)
  • Operating pressure: 0.15–1.0 MPa
  • Filtration grade: 5μm (40μm optional with mesh upgrade)
  • Pressure regulation range: 0.05–0.85 MPa
  • Flow capacity: 3,500 Nl/min (at 0.7MPa)
  • Body material: Anodized aluminum alloy (SS316L version available)
  • Seal material: NBR+PU hybrid seals (SW indicates food-grade option)
  • Temperature range: -5℃ to 60℃ (non-freezing conditions)
  • Condensate drain: Semi-automatic float-type
  • Weight: 1.85kg (dry)
  • Dimensions: 200mm(L) × 100mm(W) × 150mm(H)
  • Pressure gauge: 63mm dial, glycerin-filled (rotatable 300°)
  • Mounting: Bracket-integrated with M5 slot compatibility

Modular FRL unit combining 5μm particulate filtration and precision pressure regulation. Features anti-clogging sintered bronze filter element and shock-resistant polycarbonate bowl with metal guard. The "SW" variant includes silicone-free seals for semiconductor/pharmaceutical applications.

Typical Applications:
  • Centralized pneumatic system pretreatment
  • Plastic injection molding machine air lines
  • Automated CNC tool changers
  • Food packaging line actuator control
  • Laser cutting machine gas regulation
Maintenance protocol: Replace filter element every 2,000 operational hours or when pressure drop exceeds 0.1MPa. Bowl torque spec: 12-15N·m during reassembly. Always depressurize before servicing.
Installation guidelines:
  • Mount upstream of directional control valves (minimum 300mm from air compressor)
  • For vertical installation, orient drain port downward at ≥15° angle
  • Use PTFE tape on male threads only, avoiding sealant contamination


Property Property Value
sku GAFC200N08SW
Port Size PT1/4
Shipping policies

Returns will be accepted for up to 15 days of Customer’s receipt or tracking number on Not used items. You, as a Customer, are obliged to inform us via email before you return the item, only in the case of:

  • Received the wrong item.
  • Item arrived not as expected (ie. damaged packaging).
  • Item had defects.
  • Over delivery time.
  • The shipper does not allow the goods to be inspected before payment.

The returned product(s) must be in the original packaging, safety wrapped, undamaged and unworn. This means that the item(s) must be safely packed in a carton box for protection during transport, possibly the same carton used to ship to you as a customer.

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
 
 

Recently Viewed

Explore your recently viewed items, blending quality and style for a refined living experience.