The AirTAC GAFR Adjustable Filter Regulator GAFR20006ALJWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR20006ALJWT is a compact filter & regulator that cleans and stabilizes air pressure in a single body, eliminating the need for separate filter and regulator units. This 1/8in port model weighs just 290 g and uses a 5 um element to trap fine particles, while its automatic drain clears condensate without manual attention.
Its lower-pressure regulator delivers a steady 0.15-0.4 MPa (20-58 psi) output, ideal for sensitive equipment. The built-in circular gauge with MPa/psi scale lets you monitor set pressure directly, and the balanced mechanism holds the outlet steady as supply varies. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR20006ALJWT |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-06 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/8" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-06 (F.R.L. combination) |
Feed a single precision pneumatic valve with clean, regulated air at a stable low pressure, protecting sensitive internal components from supply fluctuations.
Power a small bench-mounted assembly jig that requires consistent clamping force at low pressure, with the automatic drain reducing maintenance on intermittent lines.
Supply filtered air to a lab instrument needing fine particle removal and a capped 0.4 MPa pressure, with the 5 um element protecting delicate orifices.
Choose this GAFR200 when you need a compact, lightweight unit for a single small actuator or jig. The 1/8in port suits low-flow lines, and the 5 um element provides finer filtration than the standard 40 um grade, though it will need more frequent servicing. The automatic drain (A) handles wet or unattended lines, while the lower-pressure type (L) tops out at 0.4 MPa, so confirm your system never needs more. No bracket (J) is included, meaning you must panel-mount it or use an existing bracket. The fitted gauge reads in MPa/psi with NPT threads. If you need lubrication downstream, order the matching GAFC200-06 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-06 combination; do not expect an oil mist from this unit.
It operates at 0.15-0.4 MPa (20-58 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 25 cc and the unit weighs 290 g. It has a 5 um element and an automatic drain.
The L type limits output to 0.4 MPa for applications that must never exceed that pressure. The J code omits the mounting bracket, so you must panel-mount it or use an existing bracket. This suits installations where the unit is fixed directly to a machine frame.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.