The AirTAC GAFR Adjustable Filter Regulator GAFR20006ALT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR20006ALT is a compact filter & regulator that combines both functions in a single body, saving space on small machines. It handles a 1/8in port with a lower pressure range of 0.15-0.4 MPa (20-58 psi), using a 40 um element to clean the air.
Its automatic drain clears condensate without manual attention, and the 25 cc bowl suits light-duty cycles. The circular gauge with MPa/psi scale is fitted, and the self-locking knob keeps the set pressure stable against vibration. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR20006ALT |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Included |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-06 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/8" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-06 (F.R.L. combination) |
Feed a single pneumatic cylinder on a benchtop assembly jig with clean, regulated air at a stable low pressure.
Supply a small air vise or a manual clamping fixture where a compact unit with automatic draining keeps operation hassle-free.
Provide a steady 0.15-0.4 MPa supply to a sensitive test fixture that requires consistent pressure without frequent manual draining.
Choose the GAFR200 for small jigs or single actuators where space is tight; the 290 g weight means it can be supported by the tubing if the included bracket is not used. The automatic drain (A) is ideal for wet lines or unattended operation, while the lower pressure type (L) tops out at 0.4 MPa, so verify your system never needs more. The PC bowl is standard, and the 40 um element handles general workshop air; the NPT thread gives an MPa/psi gauge scale. If you need lubrication downstream, order the matching GAFC200-06 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-06 combination; do not expect an oil mist from this unit.
The GAFR20006ALT is a filter & regulator with a 1/8in port, lower pressure range of 0.15-0.4 MPa (20-58 psi), max pressure of 1.0 MPa (145 psi), proof pressure of 1.5 MPa (215 psi), and temperature range of -5 to 70 C. It has a 25 cc drain bowl and weighs 290 g.
The automatic drain (A) expels condensate from the 25 cc bowl without manual intervention, making it suitable for wet lines or locations where regular draining is impractical. It differs from the blank drain option, which includes both semi-auto and manual drains.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.