The AirTAC GAFR Adjustable Filter Regulator GAFR20006LT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR20006LT is a filter and regulator combined into a single compact body, eliminating the need for separate units. It delivers lower-pressure regulation from 0.15-0.4 MPa (20-58 psi) with a 40 um element, and its 25 cc drain bowl captures condensate and solids.
This 290 g unit with a 1/8in port is built for small, precise applications. The balanced regulator holds the set pressure steady as supply varies, and the diversion structure spins air to separate liquid water and solid particles before regulation. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR20006LT |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Included |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-06 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/8" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-06 (F.R.L. combination) |
Feed a small clamping jig or a single pneumatic actuator on a benchtop assembly station, where the lower pressure range protects delicate workpieces.
Supply a small air tool or a miniature cylinder in a tight machine envelope, using the 1/8in port and lightweight 290 g body for easy mounting.
Regulate air for a laboratory test fixture or a small valve manifold, where the 0.15-0.4 MPa range provides fine control for sensitive experiments.
Choose the GAFR200 for small jigs or single actuators where space is tight and flow demand is modest. The 1/8in port suits miniature circuits, and the included mounting bracket simplifies installation. The PC bowl is standard; select metal or nylon if your environment demands it. The semi-auto and manual drains are both fitted, allowing flexible condensate removal. The L-type pressure range tops out at 0.4 MPa, so verify your system never needs more. The gauge is fitted with an MPa/psi scale. For lines needing oil downstream, order the matching GAFC200-06 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-06 combination; do not expect an oil mist from this unit.
The GAFR20006LT operates from 0.15-0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 25 cc drain bowl and weighs 290 g, with a 1/8in port and a 40 um element.
The 'L' code designates the lower-pressure type, which is limited to 0.4 MPa (58 psi) instead of the standard 0.9 MPa (130 psi). This is ideal for applications requiring gentle, precise pressure, but if your machine may ever need more, the standard type is the correct choice.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.