The AirTAC GAFR Adjustable Filter Regulator GAFR20006LWTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR20006LWTK is a filter and regulator combined in a single body, so it cleans incoming air and sets a stable outlet pressure without needing separate components. This lower-pressure model operates from 0.15 to 0.4 MPa (20-58 psi) and comes with a 5 um element for finer filtration.
Its diversion structure spins the air to drop liquid water and solid particles into the 25 cc drain bowl, while the balanced, self-locking regulator keeps the set pressure steady as supply varies. At just 290 g with a 1/8in port, this unit suits compact machines where space is tight and a separate filter plus regulator would not fit. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR20006LWTK |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Included |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-06 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/8" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-06 (F.R.L. combination) |
Feed a single pneumatic clamp or small positioning jig on an assembly bench, where the 1/8in port and 290 g body mount directly to the fixture frame.
Supply clean, regulated air to a laboratory test fixture or calibration stand that uses fine-orifice valves, benefiting from the 5 um element's finer particle removal.
Protect a sensitive pressure sensor or flow meter on a prototype line, using the lower 0.15-0.4 MPa range to keep delivery pressure gentle and consistent.
Choose the GAFR200 body for small jigs or single actuators with 1/8in piping, where its 290 g mass and 25 cc drain bowl keep the footprint minimal. The 5 um element traps finer particles than the standard 40 um, making it suitable for precision valves, though it will need more frequent servicing. This model includes the mounting bracket and a circular gauge with MPa/psi scale, and the K code adds a reverse-flow (reflux) valve as an ordering difference. It has both semi-auto and manual drains fitted, so you can drain manually or let the semi-auto function operate during pressure cycles. If your line needs oil downstream, order the matching GAFC200-06 combination instead, as this unit does not lubricate. Note that 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-06 combination; do not expect an oil mist from this unit.
The GAFR20006LWTK is a filter & regulator with a 1/8in port, working pressure range of 0.15-0.4 MPa (20-58 psi), maximum pressure of 1.0 MPa (145 psi), and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 25 cc drain bowl, weighs 290 g, and includes a 5 um element.
The K code indicates a reverse-flow (reflux) valve is fitted to this GAFR20006LWTK. It is an ordering difference that adds the valve to the unit; the catalogue defers its detailed function to a separate page, so it is specified here as a build option rather than explained.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.