The AirTAC GAFR Adjustable Filter Regulator GAFR200C06ASJWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR200C06ASJWT is a filter and regulator combined into a single body, so a 1/8in line gets both water/solid separation and steady outlet pressure from one compact unit. It runs on a 0.15-0.9 MPa (20-130 psi) range and uses a 5 um element to catch fine particles before they reach sensitive equipment.
Its metal bowl holds 25 cc of condensate, and the automatic drain clears it without manual attention. At 290 g, this is the lightest body in the GAFR series, making it a fit for small jigs or single actuators where space is tight. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR200C06ASJWT |
|---|---|
| Series | GAFR200 filter & regulator |
| Port size | 1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Bracket | Not included (J) |
| Weight | 290 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR200 | GA200 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC200-06 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR200 · 1/8" · curve to 2000 L/min |
|---|---|
| One size up | GAFR300 (curve to 3500 L/min) |
| Add a lubricator | GAFC200-06 (F.R.L. combination) |
Feed a single pneumatic valve or small actuator with 5 um filtered air, keeping fine particulates away from tight clearances.
Mount on a compact fixture or test rig where a 290 g unit with a 1/8in port fits without adding bulk.
Supply a lab instrument or gauge line with 5 um filtration and stable pressure, with the automatic drain handling condensate.
Choose the GAFR200 body for 1/8in ports and light-duty circuits; step up to a GAFR300 (60 cc bowl, 3500 L/min envelope at 0.7 MPa inlet) if you need more condensate capacity or flow. The metal bowl suits demanding environments, while the 5 um element traps finer particles than the standard 40 um grade. This model has an automatic drain, no mounting bracket, and a fitted gauge with MPa/psi scale. If oil is needed downstream, order the matching GAFC200-06 combination instead. Remember that 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC200-06 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.9 MPa (20-130 psi), max pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), temperature range is -5 to 70 C, drain bowl is 25 cc, and weight is 290 g.
The J code means no mounting bracket is included. This unit is intended for panel mounting or use with an existing bracket, so it does not ship with one.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.