The AirTAC GAFR Adjustable Filter Regulator GAFR30010ALJWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR30010ALJWT is a filter and regulator combined into a single body, so incoming air is cleaned and then set to a steady outlet pressure without needing separate parts. This model uses a 3/8in port, works in the lower 0.15-0.4 MPa (20-58 psi) band, and comes with a 5 um element for finer filtration.
Its automatic drain clears condensate without manual attention, and the circular gauge with MPa/psi scale lets you read the set pressure directly. The pressed-in self-locking knob holds the adjustment against vibration, keeping the outlet stable during operation. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR30010ALJWT |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Not included (J) |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-10 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that need cleaner air and a capped 0.4 MPa supply. The 5 um element protects fine internal passages from particle wear.
Supply a laboratory fixture or test rig where a low, stable pressure is required. The automatic drain keeps the bowl from filling during long, unattended runs.
Power a small bench press or clamping fixture at a controlled low pressure. The compact 500 g body mounts to the frame, and the gauge shows the setpoint clearly.
Choose the GAFR300 body for medium-flow lines; its 3500 L/min plotted flow envelope at 0.7 MPa inlet suits it to a single machine station, while the smaller GAFR200 tops out at 2000 L/min. The PC bowl is the standard build, and the automatic drain (A) suits wet or unattended lines. The L type caps at 0.4 MPa, so confirm the application never needs more. No bracket (J) means you mount it on an existing panel or frame. The 5 um element (W) traps finer particles for sensitive valves, and the NPT thread gives an MPa/psi gauge scale. If lubrication is needed downstream, order the matching GAFC300-10 combination instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-10 combination; do not expect an oil mist from this unit.
The pressure range is 0.15-0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, has a 60 cc drain bowl, and weighs 500 g. The port is 3/8in, and it comes with a 5 um element.
The A code specifies an automatic drain, which purges condensate without manual intervention, ideal for wet lines or remote mounting. The J code omits the mounting bracket, so you use your own panel mount or existing frame; this reduces cost when a bracket is not needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.