The AirTAC GAFR Adjustable Filter Regulator GAFR30015ALNWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR30015ALNWT is a filter and regulator combined in a single body, so it cleans incoming air and sets a steady outlet pressure without needing a separate filter plus regulator pair. This 1/2in unit covers a lower pressure band of 0.15-0.4 MPa (20-58 psi) and uses a 5 um element to trap fine particles for sensitive equipment.
Its automatic drain clears condensate without manual attention, and the 60 cc bowl holds the separated water and solids. The pressed-in self-locking knob resists vibration drift, keeping the set pressure stable on moving machinery. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR30015ALNWT |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Included |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-15 (F.R.L. combination) |
Feed a bank of fine pneumatic valves that need clean, regulated air at modest pressure. The 5 um element protects sensitive internals from particle wear.
Mount on a compact assembly station with one actuator or a small clamp circuit. The 1/2in port and 500 g mass fit tight panels without overbuilding.
Supply a lab instrument or test rig that requires consistent low-pressure air. The automatic drain keeps the bowl clear during long unattended runs.
Choose this GAFR300 body for 1/2in porting with a 60 cc drain bowl and 500 g mass, a mid-size class that suits single machines or small headers. The L type limits regulation to 0.15-0.4 MPa (20-58 psi), so confirm your line never needs more than 0.4 MPa; if it might, select the standard S type instead. The 5 um element captures finer particles than the standard 40 um, ideal for precision valves but requiring more frequent element changes. This model ships with the mounting bracket included, has an automatic drain for wet or unattended lines, and omits the gauge - the 1/8in gauge connection is there if you add one later. NPT threads with MPa/psi scale match common regional fittings. If downstream lubrication is needed, order the GAFC300-15 combination rather than this unit. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/2in port, a lower pressure range of 0.15-0.4 MPa (20-58 psi), a maximum pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 60 cc drain bowl, and weighs 500 g. The 5 um element and automatic drain are fitted, with no gauge included.
The L code sets the regulation band to 0.15-0.4 MPa (20-58 psi), which suits low-pressure circuits but cannot go higher. The N after the port means no gauge is supplied; the 1/8in gauge connection is present if you add one. This combination works for fixed low-pressure applications where a gauge is not needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.