The AirTAC GAFR Adjustable Filter Regulator GAFR30015SJNTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR30015SJNTK is a filter & regulator that combines air filtration and pressure regulation in a single body, eliminating the need for separate GAF and GAR units. This 1/2in port model handles a standard pressure range of 0.15-0.9 MPa (20-130 psi) and comes with a 40 um element to trap solid particles and liquid water.
This unit features a balanced, self-locking regulator that maintains a steady outlet pressure despite supply variations, while the diversion structure spins incoming air to separate condensate into the 60 cc drain bowl. Weighing 500 g, this GAFR300 body is a mid-size choice for applications needing reliable filtration and regulation without lubrication. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR30015SJNTK |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Not included (J) |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-15 (F.R.L. combination) |
Feed a single precision jig or clamping fixture on an assembly station, where a steady 0.15-0.9 MPa supply keeps actuation consistent and the 40 um element protects sensitive valves.
Regulate air for a machine tool's coolant or chip-removal system, using the 1/2in port to deliver adequate flow while the filter removes water and solids from the supply.
Power a pneumatic test bench with a single actuator or small manifold, where the semi-auto drain allows manual checking and the 60 cc bowl handles typical condensate between shifts.
Choose the GAFR30015SJNTK when you need a 1/2in port with a 40 um element and a semi-auto plus manual drain for flexible condensate removal. The PC bowl is the standard build, and the J code means no mounting bracket is included, so plan for a panel mount or existing bracket. The N code indicates no gauge is fitted, but the 1/8in gauge connection allows adding one later if you need to read set pressure. The K code adds a reverse-flow (reflux) valve, which is an ordering difference only. If your line requires oil downstream, order the matching GAFC300-15 combination instead, as this unit does not lubricate. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan for a supply near the maximum to achieve the highest setpoint.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-15 combination; do not expect an oil mist from this unit.
This filter & regulator has a working pressure range of 0.15-0.9 MPa (20-130 psi), a maximum pressure of 1.0 MPa (145 psi), and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C and must not freeze. The drain bowl holds 60 cc, and the unit weighs 500 g.
The K code indicates a reverse-flow (reflux) valve is fitted. This is an ordering difference that adds the valve to the unit. The catalogue does not detail its function, so refer to the full datasheet for operational details. It does not affect the filter or regulator functions.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.