The AirTAC GAFR Adjustable Filter Regulator GAFR300C10LNWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR300C10LNWT is a filter and regulator combined into a single body, saving rail space and reducing potential leak points compared to separate units. It handles a 3/8in port with a lower pressure range of 0.15-0.4 MPa (20-58 psi) and uses a 5 um element for fine filtration.
This model features a metal bowl and comes with both semi-auto and manual drains. The diversion structure spins the air to separate liquid water and solid particles into the 60 cc condensate bowl. Weighing 500 g, it is a compact unit for machine-level air preparation where precise low-pressure regulation is needed. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR300C10LNWT |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Included |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-10 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 3/8" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-10 (F.R.L. combination) |
Feed a sensitive pneumatic regulator or a precision air bearing that requires a stable, low supply pressure. The balanced mechanism holds the outlet steady as inlet pressure varies.
Provide filtered, low-pressure air to a lab fixture or test rig where fine particle removal is critical. The 5 um element protects delicate orifices and instruments.
Prepare air for a single workholding clamp or a small indexing table. The 3/8in port and 60 cc bowl suit a machine with modest air consumption.
Choose the GAFR300 body for 3/8in port applications needing a 60 cc drain bowl and a flow envelope plotted to 3500 L/min at 0.7 MPa inlet. The metal bowl (C) is a build choice; the common 1.0 MPa max pressure and -5 to 70 C range apply to all bowl materials, so confirm compatibility with your environment. The 5 um element (W) traps finer particles than the standard 40 um, which is better for precision devices but requires more frequent service. This L-type unit regulates from 0.15 to 0.4 MPa, so verify your system never needs more than that top setting. The mounting bracket is included, and the NPT thread matches the MPa/psi gauge scale. Since there is no gauge fitted, the 1/8in gauge connection is available if you add one later. For lines needing lubrication downstream, order the matching GAFC300-10 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated ceiling.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-10 combination; do not expect an oil mist from this unit.
This filter & regulator has a 3/8in port, a lower pressure range of 0.15-0.4 MPa (20-58 psi), and a maximum supply pressure of 1.0 MPa (145 psi). Proof pressure is 1.5 MPa (215 psi), and the operating temperature is -5 to 70 C. The metal drain bowl holds 60 cc, and the unit weighs 500 g. It uses a 5 um element.
The 'L' designates a lower-pressure regulator, limiting the outlet to a maximum of 0.4 MPa (58 psi) instead of the standard 0.9 MPa. The metal bowl (C) is a material choice; the pressure and temperature ratings are the same as PC or nylon bowls, so select it based on your installation environment.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.