The AirTAC GAFR Adjustable Filter Regulator GAFR400C15ALJT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR400C15ALJT is a filter & regulator with both functions in one body: it spins incoming air to separate liquid water and solid particles, then delivers a steady outlet pressure through a balanced, self-locking regulator. This 1/2in unit carries a metal bowl and a 100 cc condensate chamber, weighing 880 g.
Its lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element for standard filtration. The automatic drain clears condensate without manual attention, and the circular gauge with MPa/psi scale is fitted. No lubricator is present; if oil is needed downstream, the matching GAFC400-15 combination adds that function. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR400C15ALJT |
|---|---|
| Series | GAFR400 filter & regulator |
| Port size | 1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Bracket | Not included (J) |
| Weight | 880 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR400 | GA400 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC400-15 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR400 · 1/2" · curve to 7000 L/min |
|---|---|
| One size down | GAFR300 |
| One size up | GAFR500 (curve to 8000 L/min) |
| Add a lubricator | GAFC400-15 (F.R.L. combination) |
Feed a calibrated pneumatic press or a precision clamping fixture that requires a stable, lower regulated pressure. The balanced regulator holds the setpoint as supply varies, and the 40 um element protects sensitive valves downstream.
Supply a consistent 0.15-0.4 MPa to coolant misters or air blow-off nozzles on a machining center. The automatic drain handles condensate from wet shop air, and the metal bowl suits demanding plant environments.
Use in a lab or quality bench where a clean, regulated air source at lower pressure is needed for leak testing or calibration. The 100 cc bowl reduces drain frequency, and the gauge gives a clear local readout.
Choose this GAFR400 when you need a 1/2in port with a 100 cc metal bowl and automatic drain. The lower-pressure type tops out at 0.4 MPa, so confirm your system never requires more than that. The J code means no mounting bracket is included, and the NPT thread brings an MPa/psi gauge scale. For finer filtration, select the W option for a 5 um element. If the line needs lubrication, order the GAFC400-15 combination instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC400-15 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the unit weighs 880 g. It has a 1/2in port, 40 um element, metal bowl, and automatic drain.
The L code sets the regulated range to 0.15-0.4 MPa, suitable for applications needing a lower, stable pressure. The J code omits the mounting bracket, so you must provide your own panel mount or existing bracket. The automatic drain (A) clears condensate without manual intervention.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.