The AirTAC GAFR Adjustable Filter Regulator GAFR50020ALT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR50020ALT is a filter and regulator combined into a single body, handling both air preparation tasks without needing separate units. This 3/4in version weighs 950 g and uses a 40 um element to remove water and solid particles from the line.
Its lower-pressure regulator operates from 0.15-0.4 MPa (20-58 psi), with the automatic drain clearing condensate from the 108 cc bowl. The circular gauge with MPa/psi scale is fitted, and the mounting bracket is included for secure installation. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR50020ALT |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Set a stable 0.3 MPa supply for a sensitive pneumatic gauge or test fixture, with the balanced regulator holding the outlet steady as shop pressure fluctuates.
Feed a 3/4in header serving multiple actuators on a machining center, where the automatic drain removes condensate without manual intervention.
Protect a downstream process that must never see more than 0.4 MPa, using the lower-pressure regulator as a built-in ceiling for the air supply.
Choose the GAFR500 for 3/4in lines where a 950 g unit with a 108 cc drain bowl suits the duty cycle. The automatic drain handles wet or unattended lines, while the lower-pressure type caps at 0.4 MPa (20-58 psi) - verify this ceiling matches your application before ordering. The PC bowl and 40 um element are standard, with the included bracket simplifying panel mounting. If oil is needed downstream, order the matching GAFC500-20 combination instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure is 0.15-0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 108 cc and the unit weighs 950 g.
The A code means an automatic drain that expels condensate from the 108 cc bowl without operator action. This suits wet or unattended lines where manual draining would be impractical. The semi-auto+manual option is available if you prefer manual control.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.