The AirTAC GAFR Adjustable Filter Regulator GAFR50020LT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR50020LT is a filter and regulator combined into one body, handling both air preparation tasks without a separate filter and regulator pair. This 3/4in unit operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi) and comes with a 40 um element, making it suitable for applications with modest pressure needs.
Its 108 cc condensate bowl collects water and solids separated by the internal diversion structure, while the balanced regulator mechanism maintains a steady outlet pressure. Weighing 950 g, this unit is built for a 3/4in line and includes a circular gauge with MPa/psi scale for direct pressure reading. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR50020LT |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a delicate assembly fixture that requires a gentle, steady 0.3 MPa air supply for light pressing or positioning tasks without over-pressurizing sensitive components.
Condition air for a low-pressure spray application where consistent 0.2-0.35 MPa output is needed, while the filter removes moisture and particulates from the supply line.
Supply a single 3/4in line to a machine tool's low-pressure clamping circuit, where the 108 cc bowl handles condensate from a moderately wet air source.
Choose the GAFR50020LT when your line needs 3/4in ports and a lower regulated pressure cap of 0.4 MPa. The 108 cc drain bowl is larger than the GAFR300's 60 cc, meaning less frequent draining on a busy line. This model ships with both semi-auto and manual drains, the standard 40 um element, and the mounting bracket included. The fitted circular gauge shows MPa/psi, matching the NPT thread. If downstream lubrication is ever required, the matching GAFC500-20 combination adds a lubricator to this same body and port. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR50020LT is a filter & regulator with a 3/4in port. Its pressure range is 0.15-0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 108 cc and the unit weighs 950 g.
The 'L' code designates the lower-pressure type, which tops out at 0.4 MPa (58 psi) instead of the standard 0.9 MPa (130 psi). This is for applications that only need a modest, regulated pressure and benefit from finer adjustment within that lower band. If your machine may ever need more than 0.4 MPa, the standard type would be the correct choice.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.