
The AirTAC GAFR Adjustable Filter Regulator GAFR500C20LJNWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500C20LJNWT is a filter & regulator that combines both functions in a single body, saving rail space and reducing potential leak points compared to separate units. It handles a 3/4in port and delivers a lower pressure range of 0.15-0.4 MPa (20-58 psi) with a 5 um element for finer filtration.
This model features a metal condensate bowl with 108 cc capacity, weighs 950 g, and ships with both semi-auto and manual drains. The balanced regulator mechanism holds the outlet pressure steady as supply varies, and the pressed-in self-locking knob resists drift from vibration. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500C20LJNWT |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR500 is 1/4" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a 3/4in header supplying coolant valves and actuators on a CNC lathe, where the 5 um element protects precision solenoids from fine wear particles.
Regulate air for multi-station pallet stops and clamping fixtures on a conveyor line, with the metal bowl handling occasional water slugs without cracking.
Supply a stable 0.15-0.4 MPa band to leak-test fixtures and gauges, where the lower pressure range prevents over-pressuring sensitive test pieces.
Choose the GAFR500 body for a 3/4in port and a flow envelope plotted to 8000 L/min at 0.7 MPa inlet, stepping up from the GAFR400's 7000 L/min envelope if you need more capacity. The metal bowl suits demanding environments, while the 5 um element traps finer particles for sensitive equipment. This unit has no bracket (J) and no gauge (N), so plan for panel mounting and use the 1/4in gauge connection if you add one later. The lower-pressure type tops out at 0.4 MPa, so confirm your system never needs more. For lubrication downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Pressure range is 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C. The drain bowl holds 108 cc and the unit weighs 950 g. It has a 3/4in port, 5 um element, and both semi-auto and manual drains.
The N code means no gauge is supplied, leaving a 1/4in connection if you add one later. The J code omits the mounting bracket for installations using existing panel mounts or custom frames. Both options reduce cost when standard accessories are not needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.