The AirTAC GAFR Adjustable Filter Regulator GAFR500N20ASJTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20ASJTK is a filter and regulator combined into a single body, eliminating the need for separate filter and regulator units. This 3/4in model handles 0.15-0.9 MPa (20-130 psi) with a 40 um element, and its nylon bowl collects condensate and solids.
A balanced regulator mechanism keeps the outlet pressure steady as supply varies, while the pressed-in self-locking knob resists drift from vibration. The diversion structure spins incoming air to separate liquid water and trap solid particles, dropping them into the 108 cc drain bowl. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20ASJTK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a multi-station assembly machine header with this 3/4in unit, providing filtered and regulated air to multiple actuators from one central point.
Supply stable 0.15-0.9 MPa air to CNC fixture clamps, where the balanced regulator holds set pressure despite fluctuations in the plant supply.
Protect conveyor line pneumatic valves and cylinders from water and particles while maintaining consistent operating pressure for smooth material flow.
Choose this GAFR500 when you need a 3/4in port with a 108 cc drain bowl and 950 g mass, placing it above the GAFR400 (100 cc bowl, 880 g) in capacity. The nylon bowl (N) is a build choice with the same 1.0 MPa max and -5 to 70 C rating as PC or metal versions. This unit has an automatic drain (A) for unattended operation, no mounting bracket (J), and a fitted gauge reading MPa/psi with NPT threads. The 40 um element suits general shop air; select the W option for 5 um filtration if you need finer particle removal. The reverse-flow (reflux) valve (K) is fitted as an ordering difference. If oil is needed downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
This filter & regulator has a 3/4in port, working pressure 0.15-0.9 MPa (20-130 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C, 108 cc drain bowl, and 950 g weight.
The K indicates a reverse-flow (reflux) valve is fitted to the GAFR500N20ASJTK. This is an ordering difference from models without the K code; the catalogue defers its function details to another page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.