The AirTAC GAFR Adjustable Filter Regulator GAFR500N20LJWTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20LJWTK is a filter and regulator combined into a single 3/4in body, so it cleans incoming air and stabilizes outlet pressure without needing separate units. This lower-pressure version regulates from 0.15 to 0.4 MPa (20-58 psi) and uses a 5 um element to trap fine particles for sensitive equipment.
Its nylon bowl collects condensate and solids removed by the diversion structure, with a 108 cc capacity that reduces drain frequency. The pressed-in self-locking knob holds the set pressure steady against vibration, while the included circular gauge shows the output on an MPa/psi scale. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20LJWTK |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Not included (J) |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a bank of precision pneumatic valves that require clean, stable air at a capped pressure. The 5 um element protects fine internals, and the lower-pressure range suits delicate actuation.
Mount on a machine header feeding multiple actuators with 3/4in piping. The 108 cc bowl handles condensate from a busy line, and the 950 g body needs a solid frame bracket.
Supply a small instrument air station where pressure must stay below 0.4 MPa. The self-locking knob resists drift, and the semi-auto drain allows quick manual purging.
Choose the GAFR500 body when you need 3/4in ports and a 950 g unit that suits a machine header or multi-station line; the flow curve plots to 8000 L/min at 0.7 MPa inlet. The nylon bowl suits applications where a lighter build is preferred, and the 5 um element offers finer filtration than the standard 40 um for precision valves or instrument air. This model has no mounting bracket (J), so plan for a panel mount or existing support, and it includes both semi-auto and manual drains for flexible servicing. The lower-pressure type (L) tops out at 0.4 MPa, so confirm your system never needs more; the reverse-flow valve (K) is fitted as an ordering difference, and the NPT thread matches the MPa/psi gauge scale. If your line needs oil downstream, order the matching GAFC500-20 combination instead. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
Working pressure range is 0.15-0.4 MPa (20-58 psi), with a maximum supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C, the drain bowl holds 108 cc, and the unit weighs 950 g. It uses a 5 um element and has a 3/4in port.
The K code indicates a reverse-flow (reflux) valve is fitted to the GAFR500N20LJWTK. It is an ordering difference from standard models, and its function is detailed in the AirTAC catalogue. This unit still filters and regulates air without adding any lubrication.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.