The AirTAC GAFR Adjustable Filter Regulator GAFR500N20LT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20LT is a filter and regulator combined into one body, so it cleans incoming air and stabilizes outlet pressure without needing a separate filter plus regulator pair. This 3/4in version operates in the lower 0.15-0.4 MPa (20-58 psi) band and uses a 40 um element to trap solid particles while the diversion structure spins out liquid water into the 108 cc nylon bowl.
Weighing 950 g, this unit suits a machine header or a multi-station line where a compact footprint matters. The balanced regulator holds the set pressure as supply varies, and the pressed-in self-locking knob resists drift from vibration, keeping the outlet steady in production environments. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20LT |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feed a 3/4in machine header that runs several pneumatic actuators at a steady lower pressure, relying on the 108 cc bowl to collect condensate between maintenance shifts.
Supply a multi-station assembly line where the balanced regulator holds outlet pressure as upstream supply fluctuates, and the self-locking knob prevents set-point drift from line vibration.
Use the 0.15-0.4 MPa range for a test rig that must not exceed 0.4 MPa, with the 40 um element protecting sensitive valves from particle contamination.
Choose the GAFR500 body when your line needs 3/4in ports and a 108 cc drain bowl, which holds more condensate than the GAFR400's 100 cc bowl. The nylon bowl is a build choice with the same 1.0 MPa max pressure as PC or metal, so confirm compatibility for aggressive surroundings. This model ships with the mounting bracket, a semi-auto plus manual drain, a fitted circular gauge reading MPa/psi, and a 40 um element; upgrade to the W code for 5 um filtration or add K for a reverse-flow valve. If the line needs oil downstream, order the matching GAFC500-20 combination instead of this unit. Note that 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR500N20LT is a filter & regulator with a 3/4in port, working pressure 0.15-0.4 MPa (20-58 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C, 40 um element, nylon bowl, semi-auto plus manual drain, and 108 cc drain bowl capacity. The unit weighs 950 g and has a flow curve plotted to 8000 L/min at 0.7 MPa inlet.
The L type tops out at 0.4 MPa, which suits applications that must stay below that ceiling. If your machine may ever need more than 0.4 MPa, the standard S type with a 0.15-0.9 MPa range is the correct choice instead.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.