The AirTAC GAFR Adjustable Filter Regulator GAFR500N20LWT is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR500N20LWT is a filter and pressure regulator combined into a single body, so it cleans the air and sets a steady outlet pressure without needing two separate parts. This 3/4in model has a nylon bowl and a 5 um element, with a lower-pressure range of 0.15-0.4 MPa (20-58 psi).
Its cyclonic diversion structure spins the incoming air to throw liquid water and solid particles into the 108 cc condensate bowl, while the balanced regulator holds the set pressure as supply varies. The pressed-in self-locking knob resists drift from vibration, and the circular gauge with MPa/psi scale is fitted for direct reading. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR500N20LWT |
|---|---|
| Series | GAFR500 filter & regulator |
| Port size | 3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Bracket | Included |
| Weight | 950 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code. This unit filters and regulates only; it does not add lubrication.
| GAFR500 | GA500 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC500-20 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR500 · 3/4" · curve to 8000 L/min |
|---|---|
| One size down | GAFR400 |
| One size up | GAFR600 (curve to 12000 L/min) |
| Add a lubricator | GAFC500-20 (F.R.L. combination) |
Feeds a bank of precision pneumatic valves on a machining center, where the 5 um element protects fine internal passages and the lower 0.4 MPa ceiling suits delicate actuation.
Mounts on a machine header to filter and regulate air for multiple cylinders, with the 108 cc bowl reducing how often an operator must check condensate.
Supplies a test bench or measurement instrument that needs clean, stable pressure, with the 5 um element trapping particles that could affect readings.
Choose the GAFR500 body when you need a 3/4in port and a flow envelope plotted to 8000 L/min at 0.7 MPa inlet; it steps up from the GAFR400's 7000 L/min envelope for larger distribution. The nylon bowl is a build choice with the same 1.0 MPa max and -5 to 70 C rating as PC or metal, so confirm compatibility for your environment. This model has the semi-auto plus manual drain, the 5 um element for finer filtration, and the mounting bracket included. The L type caps at 0.4 MPa, so if your machine may ever need more pressure, select the standard S type instead. If the line needs lubrication downstream, order the matching GAFC500-20 combination rather than this unit. 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC500-20 combination; do not expect an oil mist from this unit.
The GAFR500N20LWT is a filter & regulator with a 3/4in port, nylon bowl, and 5 um element. Its pressure range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, has a 108 cc drain bowl, and weighs 950 g.
The L type limits the regulated outlet to 0.15-0.4 MPa (20-58 psi), compared to the standard 0.15-0.9 MPa. This is for applications that need a low, stable pressure and must never exceed 0.4 MPa, such as delicate actuators or air bearings.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.