verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006C3T)

The AirTAC GC200-06 FRL Unit (GC20006C3T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006C3T)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and a lubricator supplied as one matched set. This GC20006C3T is size 200 with NPT1/8 (1/8 in) ports. The filter bowl carries the standard 40 um element with a differential-pressure drain, the regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the C3 code fits an external round gauge scaled in bar for teams working to bar-based plant standards. The lubricator meters oil mist into the downstream air. Filter and lubricator bowls on this size are polycarbonate (PC). Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600, with differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, MPa, psi or bar gauge scales, and three thread types (NPT on this code). AirTAC publishes flow as curves rather than a single rated figure, so we confirm sizing and full datasheet figures for your application on request.

AirTAC GC200-06 FRL Unit (GC20006C3T) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006C3T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006C3T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006C3T) Is Used

view_module

Electronics assembly workstation

Prepares the air feeding small pneumatic actuators and vacuum circuits at an electronics assembly bench, with bar-scale readout to match European plant instrumentation.

local_shipping

Trailer component build station

Supplies filtered, regulated and lubricated air to the nutrunners, clamps and lift cylinders used at a commercial trailer or vehicle component assembly station.

air

Textile machine auxiliary circuit

Conditions the auxiliary air circuit on a textile machine - doffing cylinders, thread tensioners and small jets - with one regulator setting read in bar on the round gauge.

Is the AirTAC GC200-06 FRL Unit (GC20006C3T) the Right Station?

Size 200 with 1/8 in NPT ports is the entry point of the G range; step up to size 300, 400 or 600 for larger ports and higher flow. Drain is the differential-pressure default, with automatic (A) and manual (M) catalogue options. The 40 um element is the standard grade; the W code gives 5 um where finer filtration is needed. Here the external round gauge reads bar (scale 3); MPa (1) and psi (2) scales are alternatives, as are three thread types (NPT on this code). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006C3T) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a number here. Give us your operating pressure and flow requirement and we will confirm sizing against the datasheet on request.

The 3 in the code selects the bar scale for the external round gauge, which suits plants working to bar-based standards. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006C3T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006C3T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.