The AirTAC GC200-06 FRL Unit (GC20006F1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC20006F1T is an AirTAC GC three-unit F.R.L. set: separate air filter, pressure regulator and lubricator for compressed air only, supplied as three matched pieces so they can be spaced to suit the machine layout. This size 200 configuration has NPT 1/8 in. ports, the standard 40 um filter element and a differential-pressure drain on the filter bowl. The regulator carries the embedded square gauge with an MPa scale and adjusts from 0.15 to 0.9 MPa (20 to 130 psi) with the differential-pressure drain; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls are polycarbonate (PC) at this size.
This is a genuine AirTAC part. The G series runs from size 200 up to size 600 with ports from 1/8 in. to 1 in., and options include automatic or manual drains, a 5 um filter element, psi or bar gauge scales and an external round gauge, a reverse/check valve, G (BSPP) or NPT threads and a mounting bracket. Flow is published as curves rather than a single rated figure, so we confirm flow and other datasheet figures on request.
| Model | AirTAC GC200-06 FRL Unit (GC20006F1T) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Installed at the drop feeding an assembly bench so air screwdrivers, small clamps and bench cylinders receive filtered, regulated and lubricated air right where the work happens.
Conditions the supply to the compact cylinders and grippers on a pick-and-place gantry, with the three separate units allowing the lubricator to be placed close to the valve island.
Sets and holds regulated pressure to a light-duty pneumatic bench press used for staking and riveting, with the MPa-scale square gauge giving the operator a clear setting reference.
Size 200 is the smallest step in the G series, with a 1/8 in. NPT port; move up to 300 (1/4 in.), 400 (3/8 in.) or 600 (1/2 in.) if the circuit needs more capacity. This set keeps the standard 40 um element and the differential-pressure drain, both of which have options: automatic (A) or manual (M) drains and the 5 um (W) element. The F1 suffix fixes the embedded square gauge with an MPa scale; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
There is no single rated flow number for this unit: the catalogue publishes G-series flow as curves, not as one figure. Share your supply pressure and the cylinders or tools it will feed, and we will confirm the flow from the datasheet on request before you order.
F1 specifies the embedded square pressure gauge on the regulator with an MPa scale. Other scale codes for psi or bar and an external round gauge are catalogue options, and a gauge-code variant with no gauge can also be ordered.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.