verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006F1WT)

The AirTAC GC200-06 FRL Unit (GC20006F1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006F1WT)

GC20006F1WT is an AirTAC GC three-unit F.R.L. set: separate air filter, pressure regulator and lubricator for compressed air only. This size 200 configuration has NPT 1/8 in. ports, and the W suffix specifies the 5 um filter element instead of the standard 40 um grade, sucing circuits that are more sensitive to fine particulate. The filter bowl has a differential-pressure drain, and the regulator carries the embedded square gauge with an MPa scale and adjusts from 0.15 to 0.9 MPa (20 to 130 psi) with that drain; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls are polycarbonate (PC) at this size.

This is a genuine AirTAC part. The G series runs from size 200 up to size 600 with ports from 1/8 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves rather than a single rated figure, so we confirm flow and other datasheet figures on request.

AirTAC GC200-06 FRL Unit (GC20006F1WT) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006F1WT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006F1WT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006F1WT) Is Used

science

Laboratory pneumatic dosing

Conditions the supply to pneumatic dosing pumps and small actuators on lab benches, where the 5 um element is chosen for circuits that are more sensitive to fine particulate.

tune

Pilot and sensor air circuits

Feeds pilot-air and pneumatic sensing circuits on automated equipment, where finer filtration ahead of small pilot passages is the point of choosing the 5 um grade.

factory

Label-head air jets

Supplies the small air jets and cylinders on a labelling head, combining fine-element filtration, set pressure from the MPa gauge and oil mist for the moving parts.

Is the AirTAC GC200-06 FRL Unit (GC20006F1WT) the Right Station?

Size 200 is the smallest step in the G series, with a 1/8 in. NPT port; choose 300 (1/4 in.), 400 (3/8 in.) or 600 (1/2 in.) when the circuit needs more capacity. The key choice here is filter grade: the standard 40 um element suits general circuits, while the 5 um (W) element in this variant is specified where finer particle capture is wanted on the same filter stage. Drain is the differential-pressure type as built, with automatic (A) or manual (M) available; the gauge is the embedded square MPa type, with psi/bar scales and a round gauge as options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006F1WT) FAQ

G-series flow is published as curves, not as a single rated number, so we do not quote one figure here. Give us your supply pressure and the equipment this 1/8 in. set will feed, and we will confirm the flow from the datasheet on request before you order.

The standard element is 40 um, which covers general-purpose air prep; the W suffix in this code selects the 5 um element for circuits where finer particle capture is wanted at the same filter stage. If you are unsure which grade suits the application, tell us what the air feeds and we will advise and confirm the datasheet on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006F1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006F1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.