AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006LC1T)

The AirTAC GC200-06 FRL Unit (GC20006LC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006LC1T)

GC20006LC1T is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator mounted in line in that order. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The medium is compressed air only, with a maximum working pressure of 1.0 MPa (145 psi) and a -5 to 70 C operating window. The 200-size filter and lubricator bowls are polycarbonate.

The G series spans 200/300/400/600 sizes with ports from 1/8 in to 1 in, plus optional 5 um filtration, manual or automatic drains, alternative gauge styles and scales, and G (BSPP) or NPT thread options. Flow is published as performance curves rather than a single rated figure, so we confirm flow and full datasheet details on request before you order.

AirTAC GC200-06 FRL Unit (GC20006LC1T) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006LC1T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006LC1T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006LC1T) Is Used

factory

Air-motor agitator drive on a coatings line

Filtering, regulating at low pressure and oil-misting the air feeding a small air motor that stirs paint or resin in a day tank, keeping the drive lubricated through long batch runs.

handyman

Maintenance bench air tool station

One conditioned feed at the MRO bench for impact drivers, ratchets and die grinders, with the MPa gauge read during setup so each tool sees the pressure it was set up for.

science

Lab-scale pneumatic test rig

Supplying filtered, regulated, lubricated low-pressure air to a laboratory fixture that cycles a small cylinder, keeping scale and moisture out of the motion loop.

Is the AirTAC GC200-06 FRL Unit (GC20006LC1T) the Right Station?

Step up from 200 to 300/400/600 when the line needs more flow and larger ports (1/4 in to 1 in). This unit carries the L low-pressure regulator type, so pick the standard type instead if your process is set near the top of the pressure range; we confirm the exact setting band from the datasheet on request. Drain choices for the filter bowl are differential-pressure (fitted here), automatic or manual. Filtration is 40 um as supplied; the W variant gives 5 um for finer protection of downstream valves and cylinders. The gauge here is the round MPa version; square bodies and psi or bar scales are catalogue options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow appears only as curves, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006LC1T) FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated number, so no one figure is quoted here. Send us your line pressure, port size and air demand and we will confirm the flow from the datasheet on request before you order.

L marks the low-pressure regulator type, chosen when the downstream process is held at lower set pressures than a standard regulator is tuned for. If your line runs near the top of the pressure range, order the standard type instead; we confirm the exact setting range from the datasheet on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006LC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006LC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.