The AirTAC GC200-06 FRL Unit (GC20006LNWT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and a lubricator supplied as one treatment set. This GC20006LNWT is the 200 size with NPT1/8 ports, built as the low-pressure regulator type (L) with adjustment up to 0.4 MPa. The W in the code specifies the fine 5 um filter element instead of the standard 40 um, the bowl uses differential-pressure drainage, and no gauge is fitted (N).
This is a genuine AirTAC part. The GC family is offered in 200, 300, 400 and 600 sizes, with standard or 5 um filtration, automatic, manual or differential-pressure drains, embedded square or external round gauges scaled in MPa, psi or bar, and G (BSPP) or NPT threads as orderable options. AirTAC publishes flow as curves, so we confirm the datasheet and any sizing figures on request.
| Model | AirTAC GC200-06 FRL Unit (GC20006LNWT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Fine-filtered, regulated and lubricated air for the compact gripper and slide modules on an electronics assembly cell, with the 5 um element guarding the small pilot valves.
Oil-mist supply plus clean, low-pressure regulation for the air cylinders and bearings of a wire-processing machine.
Point-of-use F.R.L. set on the pulse-jet air line of a small dust-collection hopper, where clean low-pressure air fires the diaphragm valves.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The L variant caps regulator adjustment at 0.4 MPa; a standard GC without L gives the wider setting range. Drainage here is differential-pressure; specify M for manual or A for automatic if the duty calls for it.
Flow is published as curves rather than a single rating, so ask us to confirm sizing against the application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
There is no single rated-flow figure for the GC200 series - AirTAC publishes flow as curves that vary with inlet pressure and setting, so any single number would be misleading. Send us your pressure and consumption and we will confirm the correct size and share the datasheet curves on request.
This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Use the W suffix whenever the downstream components need finer particulate removal.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.