The AirTAC GC200-06 FRL Unit (GC20006MC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination combining a separate air filter, a pressure regulator and a lubricator in one set. This GC20006MC1T is the 200 size with NPT1/8 ports. The M in the code specifies a manual-drain bowl, so condensate is emptied by hand; with manual drainage the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). The filter carries the standard 40 um element, and C1 specifies an external round gauge scaled in MPa.
This is a genuine AirTAC part. The GC series is also made in 300, 400 and 600 sizes, with a 5 um (W) filter option, automatic or differential-pressure drains, embedded square or external round gauges in MPa, psi or bar scales, G (BSPP) or NPT thread variants and an optional check valve. AirTAC publishes flow as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | AirTAC GC200-06 FRL Unit (GC20006MC1T) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
A complete filter-regulator-lubricator set at a maintenance bench drop, keeping impact tools and ratchets lubricated with the MPa gauge in view of the operator.
Point-of-use treatment on a vehicle-service bay's 1/8 in. tap feeding air tools, with manual bowl draining at shift end.
Clean, regulated and oiled air for the glue applicator cylinders on a carton-sealing machine, with the round gauge letting operators verify the setpoint.
Pick manual drain (M) when the unit sits where an operator can bleed the bowl routinely; choose automatic (A) or differential-pressure drainage for unattended positions. This 200 size gives NPT1/8 ports for the smallest supply branches - move to 300/400/600 for larger ports and flow. The standard regulator covers 0.05-0.9 MPa with manual drain; the 40 um element suits general shop air, while the W suffix gives 5 um. The C1 round gauge reads in MPa; other scales are orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow is published as curves, not a single rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC does not state a single rated-flow figure for the GC200 series; flow is published only as curves that depend on inlet pressure and the regulator setting. We therefore do not quote a number here. Tell us your line pressure and demand and we will confirm the sizing and provide the datasheet curves on request.
The M in GC20006MC1T means condensate collected in the filter bowl must be drained by hand, which suits positions an operator visits regularly. With a manual drain the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). If you prefer the bowl to discharge itself, order an automatic (A) or differential-pressure drain variant.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.