AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MC1T)

The AirTAC GC200-06 FRL Unit (GC20006MC1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MC1T)

The AirTAC GC series is a three-piece F.R.L. combination combining a separate air filter, a pressure regulator and a lubricator in one set. This GC20006MC1T is the 200 size with NPT1/8 ports. The M in the code specifies a manual-drain bowl, so condensate is emptied by hand; with manual drainage the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). The filter carries the standard 40 um element, and C1 specifies an external round gauge scaled in MPa.

This is a genuine AirTAC part. The GC series is also made in 300, 400 and 600 sizes, with a 5 um (W) filter option, automatic or differential-pressure drains, embedded square or external round gauges in MPa, psi or bar scales, G (BSPP) or NPT thread variants and an optional check valve. AirTAC publishes flow as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

AirTAC GC200-06 FRL Unit (GC20006MC1T) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MC1T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MC1T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MC1T) Is Used

handyman

Workshop air-drop for hand tools

A complete filter-regulator-lubricator set at a maintenance bench drop, keeping impact tools and ratchets lubricated with the MPa gauge in view of the operator.

local_shipping

Trailer air-tool tap

Point-of-use treatment on a vehicle-service bay's 1/8 in. tap feeding air tools, with manual bowl draining at shift end.

build

Packaging machine glue-head supply

Clean, regulated and oiled air for the glue applicator cylinders on a carton-sealing machine, with the round gauge letting operators verify the setpoint.

Is the AirTAC GC200-06 FRL Unit (GC20006MC1T) the Right Station?

Pick manual drain (M) when the unit sits where an operator can bleed the bowl routinely; choose automatic (A) or differential-pressure drainage for unattended positions. This 200 size gives NPT1/8 ports for the smallest supply branches - move to 300/400/600 for larger ports and flow. The standard regulator covers 0.05-0.9 MPa with manual drain; the 40 um element suits general shop air, while the W suffix gives 5 um. The C1 round gauge reads in MPa; other scales are orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published as curves, not a single rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MC1T) FAQ

AirTAC does not state a single rated-flow figure for the GC200 series; flow is published only as curves that depend on inlet pressure and the regulator setting. We therefore do not quote a number here. Tell us your line pressure and demand and we will confirm the sizing and provide the datasheet curves on request.

The M in GC20006MC1T means condensate collected in the filter bowl must be drained by hand, which suits positions an operator visits regularly. With a manual drain the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). If you prefer the bowl to discharge itself, order an automatic (A) or differential-pressure drain variant.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.