verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MC1TK)

The AirTAC GC200-06 FRL Unit (GC20006MC1TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MC1TK)

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and a lubricator delivered as one treatment set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The trailing K means a reverse/check valve is fitted in the regulator, holding the downstream setting if upstream pressure is lost.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes, with a 5 um (W) filter option, automatic or differential-pressure drains, embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT thread options to order. AirTAC publishes flow as curves rather than a single rating, so we confirm the datasheet and sizing figures on request. Order code GC20006MC1TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-06 FRL Unit (GC20006MC1TK) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MC1TK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MC1TK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MC1TK) Is Used

bolt

Pneumatic clamp holding circuit

F.R.L. supply for the clamping cylinders on a fixture table, where the check valve holds the regulated setting if the shop-air main is interrupted.

valve

Diaphragm pump feed set

Filtered, regulated and lubricated air feeding a small air-operated diaphragm transfer pump, with the MPa gauge confirming the pump's supply pressure.

engineering

Press fixture safety interlock line

Treatment set on the pilot-air line of a bench press interlock circuit, where retained downstream pressure prevents an unintended release.

Is the AirTAC GC200-06 FRL Unit (GC20006MC1TK) the Right Station?

Specify the K suffix when the circuit must keep its regulated setting if supply pressure dips or is shut off - useful on clamping or holding circuits. This code pairs that check valve with manual drainage (0.05-0.9 MPa setting range), a 40 um element and a round MPa gauge on the 200 size with NPT1/8 ports. Larger 300/400/600 sizes cover bigger ports and flow; the W suffix gives 5 um filtration; automatic or differential-pressure drains suit unattended locations. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow is published as curves, not a single rated figure, so ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MC1TK) FAQ

No single rated-flow number exists for the GC200 series - AirTAC publishes flow as curves that change with inlet pressure and regulator setting, so we do not quote a figure here. Share your line pressure and air demand and we will confirm the sizing and send the datasheet curves on request.

K means a reverse/check valve is fitted in the regulator section: if upstream pressure falls away, the valve holds the regulated downstream pressure instead of letting it bleed back. Everything else in the code is unchanged - 200 size, NPT1/8 ports, manual drain, 40 um element and a round MPa gauge.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MC1TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MC1TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.