verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MF1TK)

The AirTAC GC200-06 FRL Unit (GC20006MF1TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MF1TK)

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one air-preparation set for compressed air. This GC20006MF1TK is the size 200 frame with 1/8 inch NPT ports, a manual-drain filter bowl, the standard 40 um filter element, a square pressure gauge scaled in MPa, and a reverse (check) valve fitted. The regulator sets downstream pressure anywhere from 0.05 to 0.9 MPa (7-130 psi), and the lubricator feeds an oil mist downstream.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with a choice of three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, square or round gauges in MPa, psi or bar scales, and the K check-valve option shown here. Flow figures are published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

AirTAC GC200-06 FRL Unit (GC20006MF1TK) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MF1TK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MF1TK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MF1TK) Is Used

local_shipping

Dock and tail-lift pneumatic circuits

Prepares air for dock-door actuators and small pneumatic lifts at a loading bay, where the fitted check valve guards the circuit and the manual-drain bowl is emptied during scheduled depot checks.

factory

Cell air supply with back-flow protection

Filters, regulates and lubricates air for a general production cell at the point of use, with the 40 um element for general duties and the reverse valve adding back-flow protection on the drop.

handyman

Maintenance-shop tool outlets

Serves regulated, lubricated outlets at a plant maintenance shop for hand-held air tools, with the MPa square gauge for quick setting and the check-valve option protecting the branch line.

Is the AirTAC GC200-06 FRL Unit (GC20006MF1TK) the Right Station?

This set mirrors the GC20006MF1 but adds the K reverse (check) valve, so choose it where built-in back-flow protection is wanted. The 40 um element is the standard filtration grade; the W option gives 5 um fine filtration. Manual drain pairs with the wider 0.05-0.9 MPa (7-130 psi) regulation window, and the F1 code specifies the square gauge in MPa. The 1/8 inch NPT ports are the smallest GC step; sizes 300, 400 and 600 cover higher flows.

Flow for this series is published as curves, not a single rated number, so send us your application details and we will confirm sizing and datasheet figures before you order. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MF1TK) FAQ

No: AirTAC publishes GC-series flow as performance curves rather than one rated number, so we do not quote a single rated flow. Send us your application conditions and we will confirm the matching curve and full datasheet figures on request before you order.

K fits a reverse (check) valve to the combination. Everything else matches the GC20006MF1: size 200 with 1/8 inch NPT ports, manual drain, standard 40 um element, standard regulator with 0.05-0.9 MPa (7-130 psi) adjustment, and a square MPa gauge.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MF1TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MF1TK and will confirm price, availability and lead time — usually within 7 hours.