verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MF1WT)

The AirTAC GC200-06 FRL Unit (GC20006MF1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MF1WT)

GC20006MF1WT is a genuine AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set, in size 200 with NPT1/8 ports. This configuration carries a manual drain on the filter bowl, a 5 um filtering element (the W suffix in place of the standard 40 um), and an embedded square pressure gauge reading in MPa. The regulator stage adjusts over 0.05-0.9 MPa (7-130 psi) in this manual-drain version, with a maximum working pressure of 1.0 MPa (145 psi) and a compressed-air medium throughout.

This is a genuine AirTAC part. The GC family is offered in 200, 300, 400 and 600 sizes with a choice of ports, three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um or 5 um filtration, and MPa, psi or bar gauge scales. Temperature range is -5 to 70 C (non-freezing) and the 200-size bowls are polycarbonate. AirTAC publishes flow for this series as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

AirTAC GC200-06 FRL Unit (GC20006MF1WT) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MF1WT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MF1WT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MF1WT) Is Used

precision_manufacturing

Benchtop pick-and-place cell

Feeds conditioned air to a small benchtop pick-and-place unit: the 5 um element protects fine control valves from particulates and water, the regulator sets working pressure for the grippers, and the lubricator mists the small cylinders.

science

Laboratory clamping fixture

Supplies filtered, regulated and lubricated air to a lab test fixture with pneumatic swing clamps, where the manual drain lets an operator bleed accumulated water at the start of each shift.

handyman

Workbench air-tool station

A point-of-use set at an individual workbench: it cleans, regulates and lubricates the supply feeding air screwdrivers and small ratchets, with the MPa gauge giving a clear local pressure readout.

Is the AirTAC GC200-06 FRL Unit (GC20006MF1WT) the Right Station?

Size 200 with 1/8" ports is the compact step of the GC range; if your line draws more air, step up to size 300/400/600 for larger ports and flow capacity - match the size and port to the demand rather than the fitting alone. This unit already specifies manual drain, 5 um filtration and a square MPa gauge; if you prefer hands-off water removal, ask for the automatic (A) or differential-pressure (blank) drain variant, and if your panel reads in psi or bar, the gauge scale can be ordered to match. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because AirTAC publishes flow as curves, not a single rated figure, we cannot quote one rated number here - ask us to confirm sizing against the flow curve for your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MF1WT) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote one number on the page. Send us your application details and we will confirm the flow data from the datasheet on request before you order.

The M suffix specifies a manual drain, so an operator opens the drain to expel collected water. If you would rather not rely on routine draining, the same GC200 set is available with an automatic (A) or differential-pressure (blank) drain - tell us which you prefer and we will confirm the corresponding variant and its regulator adjustment range.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MF1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MF1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.