verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MF3T)

The AirTAC GC200-06 FRL Unit (GC20006MF3T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MF3T)

GC20006MF3T is a genuine AirTAC GC-series three-unit F.R.L. combination - separate filter, regulator and lubricator assembled together - in size 200 with NPT1/8 ports. This configuration pairs a manual-drain filter bowl with the standard 40 um filtering element and an embedded square pressure gauge reading in bar, which suits panels and machines labelled in bar. The regulator adjusts over 0.05-0.9 MPa (7-130 psi) in the manual-drain version, with a maximum working pressure of 1.0 MPa (145 psi) on compressed air.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes, with three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um or 5 um filtration, and MPa, psi or bar gauge scales. Operating temperature is -5 to 70 C (non-freezing) and the 200-size bowls are polycarbonate. Flow figures are published as curves, so we confirm datasheet data on request.

AirTAC GC200-06 FRL Unit (GC20006MF3T) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MF3T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, bar scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MF3T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MF3T) Is Used

conveyor_belt

Light conveyor diverters

Feeds the air cylinders that push cartons on a light conveyor line, providing filtered, regulated and lubricated air with a bar-scale gauge that matches the rest of a European-spec machine panel.

factory

Small assembly press supply

Conditions the supply to a bench-mounted pneumatic assembly press, where the regulator sets ram pressure and the manual drain allows the water collected in the bowl to be bled during shift start-up.

air

Air knife blowing station

Supplies a small air-knife blow-off station that clears dust and droplets from parts, with the filter and regulator ensuring the blowing air is clean and held at the set pressure.

Is the AirTAC GC200-06 FRL Unit (GC20006MF3T) the Right Station?

If your plant instruments read in bar, this MPa-free configuration saves conversion errors at the point of use; MPa and psi gauge scales can be ordered instead. The 40 um element is the standard grade and suits general factory air feeding cylinders and valves; where finer protection is needed, the W variant with a 5 um element is available in the same set. Drain is manual here - choose automatic (A) or differential-pressure (blank) if the unit will be hard to reach. Size 200 with 1/8" NPT ports is the smallest step; move to size 300/400/600 as your flow demand and pipework grow.

Flow is published as curves, not a single rated figure - ask us to confirm sizing for your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MF3T) FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not state a rated number. Tell us the application and we will confirm the relevant flow data from the datasheet on request.

This code carries the standard 40 um element, which suits general-purpose air feeding cylinders and standard valves. The 5 um (W) grade is the choice when downstream equipment needs finer protection from particulates. Both grades are available in the same GC200 set - confirm the grade you need with us before ordering.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MF3T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MF3T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.