The AirTAC GC200-06 FRL Unit (GC20006MLF1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC200 series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator so a single inlet run cleans, regulates and lubricates the compressed air. This GC20006MLF1WT is the size-200 body with a 1/8 inch NPT port, a manual-drain polycarbonate filter bowl, the fine 5 um W-grade element, a low-pressure type regulator and an embedded square gauge reading in MPa.
Every set we sell is a genuine AirTAC part. The GC range runs from size 200 to 600 with ports from 1/8 inch to 1 inch, and can be ordered with a 40 um or 5 um element, differential-pressure, automatic or manual drain, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads instead of the NPT standard. Flow figures are published as curves rather than a single rating, so send us your line details and we will confirm the datasheet numbers on request.
| Model | AirTAC GC200-06 FRL Unit (GC20006MLF1WT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeding fine-filtered, regulated, lubricated air to pilot-operated diaphragm valves and actuated sample valves on a treatment skid.
Conditioning the supply to gripper cylinders and vacuum-ejector circuits on a compact pick-and-place robot cell.
Supplying stable, cleaned, oil-misted air to pneumatic test fixtures and brake-chamber rigs at a commercial vehicle service bay.
Size 200 is the smallest GC step with a 1/8 inch NPT port; move up to 300, 400 or 600 as demand grows. The M code gives a manual-drain filter bowl, convenient where the set is reachable; automatic and differential-pressure drains exist on other codes. The W element filters to 5 um instead of the 40 um standard - the choice for finer particle protection. The square gauge reads in MPa (psi and bar scales can be ordered). This is the low-pressure type regulator - confirm the adjustment span for your line pressure with us before ordering. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC range as performance curves, not as a single rated number, so we do not quote a figure here. Give us your line pressure and demand and we will confirm the sizing from the datasheet on request.
The 40 um element is the standard choice for general actuator supply; the 5 um W element on this model suits finer downstream components that need cleaner air. Both drain types and grades are available across the GC range - ask us to confirm the best pick for your line on request.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.