verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MLNWT)

The AirTAC GC200-06 FRL Unit (GC20006MLNWT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$64.12 $71.62Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MLNWT)

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, each handling its own job on the same compressed-air line. This GC20006MLNWT is the size 200 set on NPT1/8 in. ports (NPT thread), with a manual-drain filter bowl, the finer 5 um filter element, a low-pressure regulator type and no pressure gauge - a compact treatment train for small, low-pressure points of use.

This is a genuine AirTAC part for compressed air, rated up to 1.0 MPa (145 psi) working pressure and -5 to 70 C. The G series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in., plus drain, filter-grade, gauge, reverse-valve and thread (NPT on this code) options. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application on request.

AirTAC GC200-06 FRL Unit (GC20006MLNWT) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MLNWT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MLNWT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MLNWT) Is Used

science

Lab actuator bench manifold

Feeds small air cylinders and grippers on a laboratory bench from a low-pressure supply, giving one point where the air is filtered to 5 um, regulated and lubricated before it reaches the instruments.

build

Air-driven stirrer on a coating tank

Powers a low-pressure air motor driving a paint or adhesive stirrer, keeping oil mist in the supply so the motor vanes stay lubricated through long mixing runs.

handyman

Small assembly-cell tool station

Serves a single operator station running air screwdrivers or nutrunners, with one manual-drain point the operator drains at shift start and end.

Is the AirTAC GC200-06 FRL Unit (GC20006MLNWT) the Right Station?

Size 200 with 1/8 in. ports is the smallest step in the G series, best matched to small-bore supply lines and modest downstream demand - step up to GC300/400/600 when the port size or air volume of your circuit grows. The manual drain means someone drains the filter bowl by hand on a routine, so choose the automatic (A) or differential-pressure (default) drain variant instead where the unit is hard to reach. The 5 um (W) element suits lines feeding finer-toleranced components; the standard grade is 40 um. This variant has no gauge (N); gauge versions are available with MPa, psi or bar scales. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rated figure, so let us confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MLNWT) FAQ

AirTAC publishes flow for the G series as curves, not a single rated figure, so we do not quote a number here. Send us your supply pressure, downstream demand and acceptable pressure drop, and we will confirm sizing from the datasheet on request.

The L in the code marks the low-pressure regulator type, intended for circuits whose supply pressure sits well below the standard range. Its adjustment range depends on the variant, so confirm the exact setting range for your supply pressure with us before ordering. Everything else - filter, manual-drain bowl, lubricator and 1/8 in. ports - matches the standard GC200 set.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MLNWT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MLNWT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.