verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-06 FRL Unit (GC20006MNTK)

The AirTAC GC200-06 FRL Unit (GC20006MNTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$78.78 $86.28Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-06 FRL Unit (GC20006MNTK)

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator on the same compressed-air line. This GC20006MNTK is the size 200 set with NPT1/8 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. With the manual drain, the regulator setting range is 0.05-0.9 MPa (7-130 psi).

This is a genuine AirTAC part for compressed air, rated up to 1.0 MPa (145 psi) working pressure and -5 to 70 C. The G series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in., plus drain, filter-grade, gauge, reverse-valve and thread (NPT on this code) options. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application on request.

AirTAC GC200-06 FRL Unit (GC20006MNTK) Technical Specifications

ModelAirTAC GC200-06 FRL Unit (GC20006MNTK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-06 FRL Unit (GC20006MNTK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-06 FRL Unit (GC20006MNTK) Is Used

valve

Pilot-air feed for process valve positioners

Conditions and regulates the pilot air feeding control-valve positioners on a process skid, with the check valve stopping any backflow from the positioner loop toward the supply header.

factory

Single-acting cylinder circuit on a bagging machine

Runs the single-acting bag-clamp cylinders on a small bagging line, where the check valve prevents exhausted air from being pushed back through the filter-regulator set.

settings_input_component

Small air receiver top-up branch

Feeds a local air receiver from the main distribution line, with the reverse valve holding the stored charge in the receiver if the upstream supply is shut off or drops.

Is the AirTAC GC200-06 FRL Unit (GC20006MNTK) the Right Station?

Size 200 with 1/8 in. ports is the smallest step in the G series - move up to GC300/400/600 as your circuit grows. Choose this K variant when backflow through the treatment set must be blocked, for example where a downstream volume could push air backwards toward the supply. The manual drain suits an accessible mounting point; take the automatic (A) or differential-pressure (default) drain where nobody passes regularly. The standard element is 40 um and the W suffix gives 5 um. This variant has no gauge (N); gauge versions come with MPa, psi or bar scales. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rated figure, so let us confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

AirTAC GC200-06 FRL Unit (GC20006MNTK) FAQ

AirTAC publishes G-series flow as curves, not a single rated figure, so there is no one number to quote. Share your supply pressure, downstream demand and acceptable pressure drop, and we will confirm sizing from the datasheet on request - note that the fitted check valve adds a small pressure loss that we can account for in the check.

K means a reverse (check) valve is fitted in the unit, so air can pass from supply to outlet but not flow back toward the supply side. Order the K variant where a downstream volume or an exhaust path could push air backwards through the set - for example a receiver branch or a circuit with quick-exhaust behavior. The non-K GC20006MN is identical otherwise.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-06 FRL Unit (GC20006MNTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MNTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.