The AirTAC GC200-06 FRL Unit (GC20006NWT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one ordered set. This GC20006NWT is the size 200 frame with NPT1/8 ports, the finer 5 um filter element (the W suffix), the differential-pressure drain and no pressure gauge. In use it filters, regulates and lubricates a single compressed-air line: maximum working pressure is 1.0 MPa (145 psi), working temperature is -5 to 70 C (non-freezing), the bowls are polycarbonate at size 200, and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).
This is a genuine AirTAC part sold through airtacdistr.com for the US market. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 in. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. GC-series flow is published as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.
| Model | AirTAC GC200-06 FRL Unit (GC20006NWT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds the vacuum ejectors and small clamping cylinders at an electronics bench, where the 5 um element keeps fine contamination away from delicate actuation hardware.
Conditions the air for a compact pick-and-place module with solenoid valves and cylinders, with the finer element protecting the valve population that sequences the station.
Prepares the supply for lab automation equipment such as microplate handlers and small actuated fixtures, where the 5 um grade supports cleaner air than the standard element.
Size 200 with NPT1/8 ports is the entry step in the GC range; move up to sizes 300, 400 or 600 as the line's demand grows beyond a 1/8 in. connection. The W suffix on this code selects the 5 um filter element for finer particulate removal - choose the standard 40 um grade where general line protection is enough. The blank drain position is AirTAC's differential-pressure drain, which works in normal service; automatic (A) and manual (M) drains are the other orderable choices. No gauge is fitted; a square or round gauge in MPa, psi or bar scale can be ordered instead. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
Flow for the GC series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes GC-series flow as performance curves rather than a single rated figure, so we do not quote one number on this page. Tell us your line pressure and air demand and we will confirm the flow and datasheet figures for this exact unit on request before you order.
The 40 um grade is AirTAC's standard for general line protection. The W suffix, as on this GC20006NWT, selects the 5 um element for finer particulate removal ahead of sensitive valves, cylinders and instruments. If your application only needs general protection, the standard 40 um version GC20006N is the equivalent unit.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.