AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008C1T)

The AirTAC GC200-08 FRL Unit (GC20008C1T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008C1T)

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one supply set for compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and the C1 code adds an external round pressure gauge reading in MPa. Maximum inlet pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. The 200-size filter bowl is polycarbonate (PC).

This is a genuine AirTAC part offered by airtacdistr.com for the US market. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, plus options for G (BSPP) or NPT threads, automatic, manual or differential-pressure drains, 5 um or 40 um elements, gauges in MPa, psi or bar scales, and a reverse/check valve. Flow for the series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering. Order code GC20008C1T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008C1T) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008C1T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008C1T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008C1T) Is Used

factory

Assembly cell air preparation

Filters, regulates and lubricates the air feeding grippers, clamps and cylinders at a manual assembly cell, with the MPa gauge giving operators a clear supply-pressure readout.

settings_input_component

Printing machine actuator supply

Conditions air for the rollers, hold-down cylinders and registration actuators on an offset printing press, where stable regulated pressure matters print-to-print.

local_shipping

Trailer tail-lift air prep

Prepares shop air used for bench-testing and servicing trailer tail-lift cylinders and door actuators in a commercial vehicle workshop.

Is the AirTAC GC200-08 FRL Unit (GC20008C1T) the Right Station?

Size 200 with a 1/4 inch port is the common choice for general machine supply points; step up to 300, 400 or 600 when your circuit needs larger ports and greater flow capacity. The differential-pressure drain clears the bowl without daily attention, while automatic (A) and manual (M) drain codes are available. Stay with the 40 um element for general actuation, or choose the W code for a 5 um element where cleaner air is needed. The C1 gauge reads in MPa; square-gauge and psi or bar scale variants exist in the series. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. order the G (BSPP) or T (NPT) variant for other piping. Flow is published as curves, not a single rating, so ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008C1T) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote one number here. Tell us your required flow and working pressure and we will confirm the right size from the datasheet before you order.

C is the external round gauge option and 1 is the MPa scale, so this set is built with a round pressure gauge reading in MPa. Square-gauge versions and psi or bar scales are also available in the series if you prefer a different readout.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008C1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008C1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.