The AirTAC GC200-08 FRL Unit (GC20008LF1WTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC20008LF1WTK is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator set up as one group. This size 200 unit has 1/4 in NPT ports, a differential-pressure drain on the filter bowl, a fine 5 um filter element, an embedded square pressure gauge with MPa scale, a reverse/check valve, and the low-pressure (L) type regulator.
AirTAC builds the GC series in sizes 200, 300, 400 and 600, so larger port sizes and flow capacity are available in the same family if your circuit grows. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. We confirm flow and datasheet figures on request before you order.
| Model | AirTAC GC200-08 FRL Unit (GC20008LF1WTK) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Mounted at the air drop feeding a machining centre's pneumatic clamps and tool-change cylinders: filtered, regulated and lightly oiled air in one group, with the check valve holding settings if supply dips.
Prepares air for the cylinders and grippers on a carton erecting and sealing station, where the 5 um element protects the small control valves that index each box.
Feeds the divert and stopper cylinders along a sortation conveyor, keeping a single set point on the regulator while the lubricator mists the actuator seals.
Size 200 with 1/4 in NPT ports is the entry step of the G-series ladder; if your line draws more air, the same combination is available in 300, 400 and 600 with 3/8 in to 1 in ports. This version keeps the differential-pressure drain (no daily manual draining) and steps filtration down to 5 um for downstream valves and cylinders that tolerate less particulate. The regulator is the low-pressure L type, and the reverse/check valve holds upstream pressure against backflow. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options. Flow for this family is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for this series as performance curves rather than one rated number, so we do not quote a single figure. Tell us your operating pressure and demand and we will confirm the sizing from the datasheet, including whether size 200 is right or you should step to 300/400/600.
L is the low-pressure type regulator variant, and K means a reverse/check valve is fitted so downstream pressure cannot push back through the unit. Both are built into this exact configuration; the drain is the differential-pressure default and no manual bowl draining is needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.