The AirTAC GC200-08 FRL Unit (GC20008LNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC20008LNT is a genuine AirTAC G-series three-unit F.R.L. combination made up of a separate air filter, pressure regulator and lubricator. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
The GC series runs from size 200 to 600, so the same three-function group exists with larger ports and flow if you need it. We confirm flow and datasheet figures on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008LNT) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Supplies the clamp cylinders at a manual assembly bench with one filter, one set pressure and one oil-mist point, without duplicating a gauge where the panel already displays line pressure.
Prepares air entering a test station's solenoid manifold; with no local gauge, readings come from the rig's own calibrated instrumentation downstream.
Feeds impact wrenches and air ratchets at a maintenance workshop drop, where the 40 um element handles general plant air and the lubricator keeps tool motors oiled.
Choose size 200 with 1/4 in NPT ports for the smaller end of the G-series range; 300, 400 and 600 cover 3/8 in up to 1 in ports on the same family. This build uses the differential-pressure drain, so the bowl vents condensate without manual attention, and the standard 40 um element suits general plant air ahead of cylinders and common valves. The N code leaves the gauge off, which suits panels with their own instrument, but a square embedded gauge or an external round gauge in MPa, psi or bar scale can be specified instead. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as curves in the catalogue, so ask us to confirm sizing for your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as one rated figure, so we do not state a number here. Send us your pressure and consumption and we will confirm sizing from the datasheet, including whether to move from size 200 to a larger port.
The N code in GC20008LNT specifies the unit without a pressure gauge. If you want local pressure setting and display, order the variant with the embedded square gauge or the external round gauge, selectable in MPa, psi or bar scale.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.