AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008LNWT)

The AirTAC GC200-08 FRL Unit (GC20008LNWT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$64.12 $71.62Save 10% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008LNWT)

GC20008LNWT is a genuine AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator working as one group. This size 200 unit carries 1/4 in NPT ports, the fine 5 um filter element (W option), a differential-pressure drain on the filter bowl, the low-pressure (L) type regulator, and no pressure gauge (N option).

The same three-function combination is available across the G-series sizes 200, 300, 400 and 600, with larger ports and flow as you step up. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. We confirm flow and datasheet figures on request.

AirTAC GC200-08 FRL Unit (GC20008LNWT) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008LNWT)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008LNWT)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008LNWT) Is Used

science

Lab pneumatic test bench

Conditions supply air for a laboratory leak or pressure-decay bench, where the 5 um element keeps fine debris out of precision test hardware while the regulator holds the set point.

shield

Paint spray booth gun air

Feeds spray guns at a finishing booth with finer filtration ahead of the fluid tips, a stable regulated pressure, and a light oil mist for the gun's air valve.

engineering

Robot gripper air supply

Prepares air for pick-and-place robot EOAT grippers and vacuum generators, protecting small orifice components with 5 um filtration on a compact 1/4 in drop.

Is the AirTAC GC200-08 FRL Unit (GC20008LNWT) the Right Station?

Size 200 with 1/4 in NPT ports is the smallest step in the GC range; 300 to 600 extend to 1 in ports if your demand outgrows it. The W code selects the 5 um element instead of the 40 um standard, the right call when the downstream valves, cylinders or instruments are sensitive to finer particulate. Drain remains the differential-pressure type, so no routine manual draining is required, and the regulator is the low-pressure L variant. The N option omits the gauge; square embedded and external round gauges in MPa, psi or bar can be ordered instead. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow is published only as curves, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008LNWT) FAQ

No single rated number exists in the published data; AirTAC documents flow as performance curves for this series. Share your operating pressure and air demand and we will confirm the datasheet flow data and whether size 200 matches your circuit.

The W code selects the 5 um filter element in place of the 40 um standard, giving finer particulate removal for sensitive downstream components. Everything else about the decode is the same: 1/4 in NPT ports, differential-pressure drain, low-pressure type regulator, and no gauge.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008LNWT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008LNWT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.