verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MC2T)

The AirTAC GC200-08 FRL Unit (GC20008MC2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MC2T)

The AirTAC GC200-08 is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembly: a separate air filter, a pressure regulator and an oil-mist lubricator. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and the fitted round gauge reads in psi so downstream pressure can be set and monitored directly.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, thread options (NPT on this code), manual, automatic or differential-pressure drains, a 5 um (code W) filter element, gauge style and scale, and a reverse/check valve option. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request. Order code GC20008MC2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008MC2T) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MC2T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MC2T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MC2T) Is Used

factory

General plant air drop for a production cell

Installed at the point where the plant air main drops down to a production cell, the GC200-08 removes water and particulate, sets a stable regulated pressure and adds oil mist for the air tools and cylinders served by that drop.

conveyor_belt

Air supply for a conveyor drive and stopper cylinders

Mounted on the supply line feeding conveyor drive cylinders and product stoppers, this combination keeps the line's actuation pressure set at the required level, filters out pipe scale and condensate, and lubricates the cylinders in daily service.

settings_input_component

Conditioned feed to a pneumatic panel or valve manifold

Placed upstream of a pneumatic control panel or valve manifold, the unit protects the downstream valves with filtered, regulated air and supplies oil mist where lubricated actuation is specified, with the psi gauge making setpoints easy to verify.

Is the AirTAC GC200-08 FRL Unit (GC20008MC2T) the Right Station?

Start with the port step: size 200 with 1/4 in NPT ports suits lines where the required air flow falls in the 200-size band - match the size to your flow demand, since larger sizes (300/400/600) carry larger ports and more flow. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering. This unit has a manual drain, which suits installations where an operator is already on site; choose the automatic or differential-pressure drain variants if the bowl should be emptied without manual attention. The 40 um standard element covers general-purpose water and particulate removal; specify the 5 um (W) option where finer filtration is needed. The fitted round gauge reads in psi; embedded square gauges and MPa or bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MC2T) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated number, so there is no one figure we can quote for this model. Tell us your line pressure, set pressure and air consumption, and we will confirm the datasheet curve and check the sizing for your application before you order.

This configuration has a manual drain, meaning water collected in the filter bowl is released by hand during routine checks - simple and reliable where an operator is regularly present. If the unit will sit where nobody drains it routinely, choose the automatic or differential-pressure drain variants of the same series instead.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MC2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.