AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008MC2TK)

The AirTAC GC200-08 FRL Unit (GC20008MC2TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008MC2TK)

The AirTAC GC200-08 is a three-piece F.R.L. combination that conditions compressed air in one assembly: a filter removes water and particulate, a regulator sets and holds downstream pressure, and a lubricator adds oil mist for air tools and cylinders. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The regulator adjustment range with manual drain is 0.05-0.9 MPa (7-130 psi). The filter and lubricator bowls are PC (polycarbonate) at this size.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of port sizes, three thread types (NPT on this code), manual, automatic or differential-pressure drains, 40 um or 5 um (W) filtration, gauge scale in MPa, psi or bar, and a reverse/check valve option. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application. Order code GC20008MC2TK has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008MC2TK) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008MC2TK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008MC2TK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008MC2TK) Is Used

precision_manufacturing

Pneumatic press cell

Feeding a workholding or light-assembly press circuit: the filter strips water and swarf from the shop air, the regulator holds a stable set pressure for consistent clamping, and the lubricator mists oil to the press cylinder seals and valves.

conveyor_belt

Packaging line cylinder drives

Supplying the air cylinders on a carton-forming or case-packing conveyor: clean, regulated, lubricated air keeps the diverters and pushers cycling smoothly through a full shift, with the manual drain emptied at scheduled checks.

build

Assembly bench air drops

Conditioning the supply to a technician's bench where air tools are plugged in all day: the 40 um filter catches pipe scale and condensate, the psi gauge shows the set pressure at a glance, and the lubricator keeps impact drivers and ratchets running.

Is the AirTAC GC200-08 FRL Unit (GC20008MC2TK) the Right Station?

Start with the port and size step: the GC series runs 200/300/400/600, and the right step depends on the air consumption of the downstream circuit, so have us check the published flow curves against your demand before ordering. Then choose the drain: manual (as on this unit) means someone opens the drain periodically; automatic drains collected water by itself; differential-pressure is the default. Filter grade is 40 um standard or 5 um with the W code if finer filtration is needed. The gauge can be the embedded square type or an external round gauge, with MPa, psi or bar scales; this unit carries a round psi gauge. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Flow for this family is published as curves, not a single rating, so please ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008MC2TK) FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one number we can quote. Tell us your operating pressure and the air consumption of the downstream equipment, and we will confirm the sizing from the datasheet before you order.

The M in the code GC20008MC2TK means the filter bowl has a manual drain: condensate collects in the PC bowl and someone opens the drain at intervals. If you would rather not rely on scheduled checks, the GC series is also offered with an automatic drain (code A) or the differential-pressure drain that is the default, in the same sizes and ports.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008MC2TK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008MC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.