The AirTAC GC200-08 FRL Unit (GC20008MF1TK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC series is a three-unit air preparation combination: a separate filter, pressure regulator and lubricator that together clean, regulate and oil-mist lubricate compressed air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The trailing K means the reverse (check) valve option is fitted on this unit.
It is a genuine AirTAC part rated for compressed air at up to 1.0 MPa (145 psi) working pressure between -5 and 70 C (non-freezing). The GC range steps through 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and drain, filter grade, gauge, thread and check-valve options to suit the installation. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and sizing on request. Order code GC20008MF1TK has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GC200-08 FRL Unit (GC20008MF1TK) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Preparing air for gripper and tool-change circuits on a robot cell, specified with the K check-valve option; the filter, regulator and lubricator condition the supply for the gripper actuators.
Conditioning supply to the directional valves on a palletizer, with line pressure set from the embedded MPa gauge and the reverse valve fitted exactly as the panel schedule specifies.
Running the leveller and door actuators at a distribution hub; the three units clean, regulate and lubricate the supply, with the fitted reverse valve completing the specified configuration.
Step through the decodable choices in order: the 200 size with 1/4 inch NPT ports is the lightest branch-line step, with 300, 400 and 600 above it for higher air demand. This version has the manual drain (periodic attention; automatic and differential-pressure drains are the other options), the standard 40 um element, the embedded square MPa gauge (round gauges and psi or bar scales are alternatives) and, unlike GC20008MF1, the K option fits a reverse (check) valve - order the code without K where the valve is not wanted. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not one rated number, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
Flow for the GC series is published as pressure-drop curves, not as a single rated figure, so there is no one number we can quote. Send us your line pressure and air demand and we will confirm the correct size and the datasheet figures on request before you order.
K indicates the reverse (check) valve option is fitted to this unit; the identical code GC20008MF1 without the K is supplied without it. Order the version your circuit drawing calls for, since the option is built in at the factory rather than added afterwards.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.